8. Connection unit
Fault codes
If a fault arises, the fault code is shown in the display in the form of a letter for identifying the fault, followed by numbers and/or number
segments for further information, followed by sensor indication (C) in accordance with the previous page.
In fault codes E, F and U, the numbers (1-9) show which control device/output the fault code refers to.
1
CTRL 1
Fixed control device 1, including two-hand button 2h1
2
CTRL 2
Fixed control device 2, including two-hand button 2h2
3
CTRL 3
Radio control device, External
4
CTRL 4
Coil control device
5
CTRL 5
Slider lift control device
6
CTRL 6
Radio control device, internal module
7
CS
CS (cabin switch)
8
Control Power
9
Sensor Power
If the system discovers several faults, only the fault code for the fault with the highest priority will be shown auto-
matically. The display is prioritised in the order in the table below, L/H, E, F, and A. To see all current faults, press
and hold in button C on the control device.
When the CS is switched off, the system will browse through a list containing the five most recent faults detected before
the display goes off after approx. 5 minutes, the control card then goes into power save mode.
Fault codes
Identification
Code 1 Code 2 Code
3
Information
Other
L
Low battery voltage
07-35
Voltage measured
H
High battery voltage
07-35
Voltage measured
E
Control device
locked
1
Fixed control device 1 (incl. two-hand
button 2h1 if they are monitored)
2
Fixed control device 2 (incl. two-hand
button 2h2 if they are monitored)
3
Radio control device, external
4
Coil control device
5
Truck slider control device
6
Radio control device, internal module
7
CS (cabin switch)
Segment
Segments B, C, E or X are illumi
-
nated depending on which button
locks the control device.
B
C
E
X
In
Out
F
Output short-circuit-
ed/high current
0-9
Which output has short-circuited/
has high current. Fault code is
reset automatically if the function
in question is running (function
verified).
1-7 U 0 - U 7 , d i s -
played only after
the respective
output/function
has been active.
8 Control power
9 Sensor power
Output not connect-
ed/cable breakdown
0-7
Which output is not connected/has
cable breakdown. Fault code is reset
automatically if the function in ques-
tion is running (function verified).
Displayed only af-
ter the respective
output U0-U7 has
been active.
A
Internal fault
0-
Any measurement faults are reg-
istered by the system.
Contact support
if the lift does not
function.