8. Connection unit
Information codes
Codes are shown on the display in a sequence. First a letter for identification of information, followed by
figures or segments for further information and then ending with a pause:
When the CS (cabin switch) is switched on, the current program configuration (P) is displayed first, followed
by configuration number. The number of volts detected is then displayed and, after this, the current software
version (J), followed by version number.
As long as no control device is used, a scrolling sequence is then displayed, with sensor indication (C), fol-
lowed by 0-6 segments showing which sensors have a signal.
When a control device is used, the control device being used (1-7) is displayed, followed by which button
has been pressed, segments B, C, E or X (X symbolises the 4th button on the respective control device (2h1
for fixed control device 1, 2h2 for fixed control device 2, lock knob for radio control device and coil control
device).
The control devices are symbolised by the figures 1-7
1
CTRL 1
Fixed control device 1, including two-hand button 2h1
2
CTRL 2
Fixed control device 2, including two-hand button 2h2
3
CTRL 3
Radio control device, External
4
CTRL 4
Coil control device
5
CTRL 5
Slider lift control device
6
CTRL 6
Radio control device, internal module
7
CS
CS (cabin switch)
Once a button has been released, the control system for the current control device is locked for a while to
ensure that no other person operates the lift from another control device. During the period the control sys-
tem is locked for the current control device, its number (1-7) will flash on the display. This primarily applies to
radio and coil control devices, as other control devices have such a short locking period that there is hardly
time to see the indication.
Coil control devices can be equipped with a locking function. Once the control device has been used, the
control system is locked for the current control device until it is unlocked manually from the respective control
device’s deactivation button. With some configurations, however, the coil control device can, for safety rea
-
sons, always tilt the platform down in the event of the operator getting shut inside.
The radio control device is also equipped with a locking function. The control system can then be locked/
unlocked by pressing and holding button 5. The lock’s status is indicated by the locking function LED, which
comes on when the lock is activated. In the event of a fault in the remote control, unlocking can be performed
by turning the control power (CS) Off/On.
On certain remote control models the lift is locked again as soon as a button on the remote control is pressed
when the lift is unlocked through the control power being turned Off/On.
The lift remains locked if it loses power and is then started up again, and the number 6 flashes
on the control card’s display. Unlocking is performed as described above.
NOTE.