5. Electrical installation
Cable routing of earth and supply cable to the lift.
Due to the risk of cables being pinched and / or
damaged which can lead to short circuits and cable
fire, the earth and supply cable should be mounted
outside the clamping bracket (see photos above).
They must also be sufficiently far away from edges
so there is no risk for abrasion.
Also make sure that the routing of cables is done
with similar care to avoid damage from contact with
edges of the frame and other parts of the vehicle.
This will increase the life of the cables and reduce
the risk of unnecessary downtime
Connection of non-original components on zepro
tail lifts
It has always been forbidden to connect foreign
equipment (both electric and hydraulic) on all
Zepro tail lifts. Using non-original components can
affect tail lift safety. If it's really important for you
to make such installations please check with the
vehicle manufacturers installation instructions and
use the trucks capabilities.