18 - D2O VCP Product Manual
7.1 INTRODUCTION
This section provides information on all of the Serial Commands that may be
entered into the CLI.
When entering any command (and any relevant parameter) it must be
followed by a carriage return control character, which is sent by pressing the
Enter
key on the user’s keyboard.
The commands are case sensitive with some characters used in both upper
and lower case forms.
Dates and times used for the D2O are all based on Greenwich Mean Time
(GMT).
The commands are split into category groups as follows:
GROUP
DETAILS
-
Admin Parameters
sys
D2O Unit System Parameters
time
System Time Parameters
gps
Global Positioning System (GPS) Parameters
acq
Data Acquisition and Configuration Parameters
msg
Satellite Network Coverage and Transmission Parameters
inp
External Device Input Parameters
As a first step it is highly recommended to change the default password. Use
the CLI to complete the following, pressing the
Enter
key after each line,
noting the text entered is case sensitive:
1. Enter admin mode to allow the editing of system settings (requires the
admin password; The default is:
password
):
admin password
Note that if the password has previously been changed from the default,
you will need to enter the currently set password.
2. It is recommended to change the default password. This command
requires the new password to be entered twice, separated by a single
space. The password cannot contain whitespace. Example below using
newpassword
as the new password:
sys -P newpassword newpassword
3. Apply the changes to the parameters:
apply A
The D2O’s administration password has now been changed.
7.2 ADMINISTRATION SETTINGS