D2O VCP Product Manual - 13
5.1 BEFORE STARTING
Before the D2O VCP unit can perform its normal operation it must be
programmed to establish the desired operating parameters. Without a valid
program, the D2O will not know how to communicate to the attached voltage,
current or pulse counter devices.
The D2O VCP can be programmed either prior to installation or during
the installation process. In either scenario the external device(s) must be
connected to the D2O VCP at the time of commissioning in order to correctly
setup and test the system. See the Wiring Guide section of this product
manual for more information on connecting devices and the D2O VCP
Programming section for more information on programming the D2O.
The information in this section relates to the basic operation of the D2O unit
and explains the main interfaces.
5.2 STARTING THE D2O
Using a coin or wide flat blade screw driver, rotate the
Battery Switch
through
45° to the
ON
position. The
ON
position is indicated by the “I” character on the
enclosure.
The translucent Battery Switch will then flash a green signal light 3 times to
indicate it is powered on. This can take up to 1 minute to occur. If the light
does not flash green please refer to the Operational Troubleshooting section.
After the unit is powered it will begin its start-up sequence, which includes
attempting to obtain a Global Positioning System (GPS) fix to update its
location and internal time clock.
IMPORTANT NOTE:
If operating indoors the unit may not achieve a GPS fix
and the D2O will not receive updated location and time
clock data. Other functionality can still occur but it is
recommended to obtain a GPS fix first.
5.3 SHUTTING DOWN THE D2O
Before the D2O can be shut down, ensure there is no active USB connection
via the
4-Pin M12 to USB-A
cable. The D2O will remain powered by the USB
supply, even if the
Battery Switch
is in the
OFF
position.
The D2O can be shut down by rotating the
Battery Switch
through 45°, using
a wide flat blade screw driver or coin, to the
OFF
position. The
OFF
position is
indicated by the “O” character on the enclosure.
The unit will then be shut down. A red signal may briefly flash through the
translucent
Battery Switch
during this process.
No data will be collected, transmitted or received while the D2O is shut down
and the
Battery Switch
is in the
OFF
position.