PV152
3-9
PRO1200 ADJUSTMENTS
ADJUSTMENTS
10. Connect the probe of the oscilloscope to the pin 1
of the IC30.
11. Adjust the potentiometer P6 for a correct clamping
level of the Vertical parabola (see fig below).
RGB Input+Switching Module
Signal input: Oscillator Period Adjustment
Adjustment of the Oscillator period in the IC 801 Re-
quires
no signal
.
1. Connect an oscilloscope to pin 2 of the connector
J400. Adjust the potentiometer P800 for a period of
the Sandcastle pulse of 64us.
2. Input GAIN adjustment Red (P200) channel.
Connect a RGB/S signal to the RGB-HS/CS inputs and
select RGB/S.
Fig. BB
Schematic Reference:
Page: 6-25
Sect: A-3
+5V
+5V
R237
R233
3K
3
10K
D31
BAT54
D30
BAT54
R321
22K
C706
4K7
R320
1K
R322
180K
IC16
LM393
1
2
3
-12V
+12V
P3
50
K
DC OFFSET
SWITCHING LEVEL
ADJUSTMENT
ON 407
TRIGGER POINT J411
P3 aligned correctly
Fig. CC
Schematic Reference:
Page: 6-25
Sect: E-4
R220
3K
3
AD835
Z
VP
W
VN 3
8
6
2
5
4
2
+5V
-5V
C59
C64
100K
100K
22
K
R231
R319
1K
>J625[2]
>SHEET 7
VP_SIM
>SHEET 3
VP-
R198
1K2
-12V
+12V
P6
50
K
R318
150K
1K2
R200
IC15
TL082
6
5
7
1Vpp
1Vpp
<0>
VERTICAL
PARABOLA
ADJUSTMENT
CLAMPING LEVEL
VERTICAL PARABOLA
ON J406
TRIGGER POINT J411
P6 aligned correctly
<
C805
2n7
P800
10
K
R806
3
0K
C806
1n
C807
2 2 u
+
C808
1 0 n
Fig. EE
Schematic Reference:
Page: 6-42
Sect: F-4
SMPS
RGB Input & Switch
Sync & Vertical Deflection
Horizontal Deflection
Magentic Focus & H-Shift
Internal
Remote
Control
RGB Analog Auto Sync Input
SMPS 2+G2
EHT
Fig. DD