804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01 

Page 5 of 20

Important Safety Instructions

What is the Zenith HydroTap ?

The Zenith HydroTap CS taps are electronically controlled, filtered, Chilled and Sparkling water, drinking 
systems for kitchens and tea rooms. In addition, the Celsius tap is designed to dispense Chilled and Sparkling 
water as well as Ambient and Hot water, from external mains and hot water services respectively. 

The HydroTap units are under bench drinking water appliances with a dispensing tap mounted on a sink 
or bench, which may be used for commercial applications.  These units utilise a conventional refrigerant 
compressor to chill the water and utilise a CO

2

 gas cylinder to carbonate the chilled water. The CS models 

will dispense chilled water (factory set to 3-5°C)  These models are NOT designed to be used for sanitary 
fixtures.

In addition, there are various energy saving options accessible via the main menu. The 2.64kg CO

2

 bottle is 

refillable and should be returned to your nearest HydroTap agency for exchange, whereas the water filter is a 
disposable item. Both will require periodic replacement and are covered by a limited OEM warranty.
It is important that the Installation be done safely, correctly and completely, in order to utilise all the benefits 
the HydroTap can provide. The Classic tap may be ordered with the Tap Head Assembly for Disabled use. 
The disabled levers are supplied with Braille caps for the visually impaired. 
This manual contains important safety, Installation instructions for the Zenith HydroTap G4.

Safety

This appliance is not intended for use by persons (including children) with reduced physical, 
sensory or mental capabilities, or lack of experience and knowledge, unless they have been 
given supervision or instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not play with the appliance.
For products sold in Europe, this appliance can be used by children aged from 8 years and above and 
persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they 
have been given supervision or instruction concerning use of the appliance in a safe way and understand 
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be 
made by children without supervision.

Refrigerant

The Zenith HydroTap unit contains R134A refrigerant under pressure. Maintenance of the refrigeration unit 
must be carried out by an accredited service provider or qualified refrigeration technician.

Qualifications

If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all 
Installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power 
outlet must be in a safe visible position for connection.

Venting

Ensure the tap body is located so the tap outlet safely dispenses into the sink bowl area. 

Lifting

Take care when lifting the Zenith HydroTap unit. Some units may exceed safe lifting limits. If you feel this is 
beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked 
on the packaging. Do not lift the unit by the front cover or any connections at the top rear of the unit. Refer to 
the technical specifications for the weight of your product. 

Airflow

The ambient operating temperatures, when installed in a cupboard, must be between 5ºC -  35ºC. The 
system will operate satisfactorily only if proper air ventilation is provided and only if the recommended air 
gaps of 50mm on each side are provided. See section 2 for correct ventilation details. 

Содержание HydroTap

Страница 1: ...stallation Instructions 09 2016 v3 01 Page 1 of 20 Zenith HydroTap Installation Instructions Filtered Chilled and Sparkling drinking water for commercial kitchens and tea rooms Affix Model Number Labe...

Страница 2: ...terchangeable taps to suit the customer s needs See options below For ease of installation it is recommended to fit the tap before installing the undersink unit The installation procedure for each of...

Страница 3: ...gram CS Models 10 11 2 3 Alternative Ventilation 11 STEP 3 Fit the CO2 Gas cylinder Section 3 CO2 Cylinder and Regulator 3 1 Connect secure and test the CO2 gas cylinder 12 3 2 Connect the regulator 1...

Страница 4: ...the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Flush the supply line before connecting to the undersink unit 3 Check all plumbing fittings have b...

Страница 5: ...s they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the applia...

Страница 6: ...ature 9 Due to the process of continuous improvement Zenith Heaters reserves the right to change details mentioned in this manual without notice 2 64 Kg CO2 Cylinder Warnings Pressurised container Pro...

Страница 7: ...ir and water filters 1 off Mains water connection hose Duct kit 1 x Air Duct 1 x Mounting plate Vent Kit 1 x Kickboard louvre 1 x Door vent louvre 1 x Front vent grill 1 x Tee piece for Celsius model...

Страница 8: ...5 kg when full of water Capacity Boiling cups Capacity Chilled glasses Boost 10A GPO s Required Power Rating kW Boost Rating kW Unit Dimensions W x D x H mm Dry Weight Kg Chilled Sparkling Classic Eli...

Страница 9: ...potable water supply connection with isolating valve inside the cupboard within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the...

Страница 10: ...nstall vent duct and louvre panels for under floor and or door vent systems Note Inlet and outlet vents should be separated by a Min 100mm to avoid hot air recirculation When installing air flow ducts...

Страница 11: ...d then it is important to fit a standard HydroTap vent kit which ensures heat dissipation through natural convection via installed vents For high use applications where the cupboard space temperature...

Страница 12: ...ttle regulator and cradle assembly can comfortably fit with sufficient clearances before securing the cradle inside the cupboard Due to regulatory requirements the gas bottle must be stored securely a...

Страница 13: ...est fittings Insertion and removal Be careful when cutting the poly tube so that there are no rough edges and that the tube is not distorted 1 Use a sharp knife to ensure the tube has a clean straight...

Страница 14: ...ty Initial bottle pressure will be 35 40 bar This gauge shows the adjustable limit 2 7 3 0 bar required for the HydroTap to function correctly Pressure regulating knob ON OFF knob Green zone Relief va...

Страница 15: ...n a clockwise direction to between 2 7 3 0 bar green zone NOTE The arrow should sit in the green zone of the regulator gauge it should not fall in the red or yellow sections 4 3 Test for gas leaks Whe...

Страница 16: ...mance and therefore CANNOT be lengthened Take time to consider hose lengths when determining the mounting positions for the options Note Mains hose length is 750mm Plug and Cord length is 1800mm Posit...

Страница 17: ...ength is 750mm Plug and Cord length is 1800mm Position the under sink unit close to the outlet tap within reach of the hose and cord lengths supplied Note Note All All silicon tubes silicon tubes must...

Страница 18: ...S of the cartridge is a flush line approx 600mm long and the flush line stop cock Place the valve end of the flush line into the 10L bucket or container 5 2 Filter Flush Section 5 Commissioning 5 1 CO...

Страница 19: ...ilter check user guide Water leak Isolate mains Water leak Turn off mains water supply Call for service Compressor over run Compressor too Hot Check ventilation Water supply failed No water Check wate...

Страница 20: ...5601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 US5099825 and SA2006 08043 Other patents are in force and patent applications are pending Head Office Zenith Heaters Limited IRD No 95 64...

Отзывы: