background image

Page 20 of 20 

    804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01

Contact Details

The standard cup referred to in this publication is 167 ml (6 fl oz). 
The standard glass is 200 ml (7 fl oz). 
The terms “Zenith” and “HydroTap” are registered trade marks of Zip Heaters 
(Aust) Pty Ltd. 
Zenith products described in this publication are manufactured under one or 
more of the following patents: AU675601, AU637412, AU635979, GB0422305, 
GB2065848, US4354049, US5103859, US5099825 and SA2006/08043. Other 
patents are in force and patent applications are pending.

Head Office

Zenith Heaters Limited,
IRD No. 95 640 729
Unit 2/15 Moselle Avenue,
Henderson.
Auckland.  0610
New Zealand.

Website: www.zenithheaters.co.nz

Int. Phone: +(64 9) 838 8612
Telephone: 0800 558055
Facsimile:   0800 559055

As Zenith policy is one of continuous product improvement, changes to 
specifications may be made without prior notice. Images in this booklet have 
been modified and may not be true representations of the finished goods.

WMKA00099

AS 3498 

Содержание HydroTap

Страница 1: ...stallation Instructions 09 2016 v3 01 Page 1 of 20 Zenith HydroTap Installation Instructions Filtered Chilled and Sparkling drinking water for commercial kitchens and tea rooms Affix Model Number Labe...

Страница 2: ...terchangeable taps to suit the customer s needs See options below For ease of installation it is recommended to fit the tap before installing the undersink unit The installation procedure for each of...

Страница 3: ...gram CS Models 10 11 2 3 Alternative Ventilation 11 STEP 3 Fit the CO2 Gas cylinder Section 3 CO2 Cylinder and Regulator 3 1 Connect secure and test the CO2 gas cylinder 12 3 2 Connect the regulator 1...

Страница 4: ...the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Flush the supply line before connecting to the undersink unit 3 Check all plumbing fittings have b...

Страница 5: ...s they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the applia...

Страница 6: ...ature 9 Due to the process of continuous improvement Zenith Heaters reserves the right to change details mentioned in this manual without notice 2 64 Kg CO2 Cylinder Warnings Pressurised container Pro...

Страница 7: ...ir and water filters 1 off Mains water connection hose Duct kit 1 x Air Duct 1 x Mounting plate Vent Kit 1 x Kickboard louvre 1 x Door vent louvre 1 x Front vent grill 1 x Tee piece for Celsius model...

Страница 8: ...5 kg when full of water Capacity Boiling cups Capacity Chilled glasses Boost 10A GPO s Required Power Rating kW Boost Rating kW Unit Dimensions W x D x H mm Dry Weight Kg Chilled Sparkling Classic Eli...

Страница 9: ...potable water supply connection with isolating valve inside the cupboard within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the...

Страница 10: ...nstall vent duct and louvre panels for under floor and or door vent systems Note Inlet and outlet vents should be separated by a Min 100mm to avoid hot air recirculation When installing air flow ducts...

Страница 11: ...d then it is important to fit a standard HydroTap vent kit which ensures heat dissipation through natural convection via installed vents For high use applications where the cupboard space temperature...

Страница 12: ...ttle regulator and cradle assembly can comfortably fit with sufficient clearances before securing the cradle inside the cupboard Due to regulatory requirements the gas bottle must be stored securely a...

Страница 13: ...est fittings Insertion and removal Be careful when cutting the poly tube so that there are no rough edges and that the tube is not distorted 1 Use a sharp knife to ensure the tube has a clean straight...

Страница 14: ...ty Initial bottle pressure will be 35 40 bar This gauge shows the adjustable limit 2 7 3 0 bar required for the HydroTap to function correctly Pressure regulating knob ON OFF knob Green zone Relief va...

Страница 15: ...n a clockwise direction to between 2 7 3 0 bar green zone NOTE The arrow should sit in the green zone of the regulator gauge it should not fall in the red or yellow sections 4 3 Test for gas leaks Whe...

Страница 16: ...mance and therefore CANNOT be lengthened Take time to consider hose lengths when determining the mounting positions for the options Note Mains hose length is 750mm Plug and Cord length is 1800mm Posit...

Страница 17: ...ength is 750mm Plug and Cord length is 1800mm Position the under sink unit close to the outlet tap within reach of the hose and cord lengths supplied Note Note All All silicon tubes silicon tubes must...

Страница 18: ...S of the cartridge is a flush line approx 600mm long and the flush line stop cock Place the valve end of the flush line into the 10L bucket or container 5 2 Filter Flush Section 5 Commissioning 5 1 CO...

Страница 19: ...ilter check user guide Water leak Isolate mains Water leak Turn off mains water supply Call for service Compressor over run Compressor too Hot Check ventilation Water supply failed No water Check wate...

Страница 20: ...5601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 US5099825 and SA2006 08043 Other patents are in force and patent applications are pending Head Office Zenith Heaters Limited IRD No 95 64...

Отзывы: