Page 12 of 20
804050NZ- CS Commercial HydroTap - Installation Instructions - 09.2016 v3.01
Section 3
2.640 KG - CO
2
Cylinder
STORAGE WARNING:
This cylinder mus be installed in an open plan area or in an enclosed room, with a volume no less than 50m
3
.
If more than 1 gas cylinder containing CO
2
is present within the same location, the recommended ventilated
area should be in proportion to the number of gas cylinders stored in that location.
A ventilated area is a non-enclosed area which could include the kitchen, living room etc.
See gas bottle and MSDS sheet for a complete list of warnings. (See: www.Zenithwater.com)
3.1
Secure the cylinder cradle
After removing all packing material, mark out the cradle location, and fit it on a suitable wall, within 1 metre
of the unit. Make sure the gas bottle, regulator and cradle assembly can comfortably fit, with sufficient
clearances, before securing the cradle inside the cupboard. Due to regulatory requirements the gas bottle
must be stored securely and in an upright position. Secure the bottle with the hook-and-loopstraps provided.
3.2
Connect the regulator:
After removing all packing material, fit the regulator to the gas bottle, as shown in the diagrams. Ensure the
plastic seal is fitted securely inside the large chrome nut, before attaching to the gas bottle. If the plastic seal
is not an easy fit over the spigot, soak it in hot water, before re-applying. Do not force the seal to fit.
Turn the regulator OFF by rotating the regulator knob, all the way out, in an anti-clockwise direction.
NOTE:
Two plastic seals are supplied with a new regulator. Only one is required, the other is supplied as
a spare part.
3.3
Connect the gas hose:
Connect the braided gas hose to the threaded end to the regulator (Do not lose the small sealing olive).