807041NZ v1.00 03.21 HydroTap G5 UltraCare User guide

8

 SECTION 2: Tap operation

2.2 Touch-Free Wave 

Touch-free

Controls 

Touch-free 

sensors on the tap top, 
back and sides.

Touch-free

Lights

Dispense  

sensors

Safety  

sensor 

 (at back)

Light

Touch-free

Touch-free

Clearance requirements

100mm

100mm

100mm

100mm

RED

 Boiling & safety 

sensors activated, water 
dispensed. 

BLUE

 Chilled sensor  

activated, water dispensed. 

WHITE

 Sparkling sensor 

activated, water dispensed.

PURPLE 

 Lock mode on (when tap is idle). 

Flashing RED

 Sensor activated incorrectly; hand 

may be too close to sensor, sensor has been 
touched or covered. 

WHITE / BLUE / RED Cycling 5 to 10 seconds

Filter needs replacing, CO2 warning (G5), unit 
is in an error mode (refer to Command Centre 
screen).

WHITE Flashing rapidly 

Sensors calibrating when 

power is first applied to the tap. Allow 10 seconds.

Содержание HydroTap G5 UltraCare BCU 40

Страница 1: ...807041NZ v1 00 03 21 HydroTap G5 UltraCare User guide 1 UserGuide HydroTap G5 UltraCare BCU 40 Visit our website to download the manuals...

Страница 2: ...807041NZ v1 00 03 21 HydroTap G5 UltraCare User guide 2...

Страница 3: ...erature settings 20 3 5 3 Dispense times 22 3 5 4 Light sensor 22 3 5 5 Quiet mode 23 3 5 6 Advanced settings 1 23 3 5 7 Advanced settings 2 Wave Tap only 24 3 5 8 System restart 24 3 6 Safety securit...

Страница 4: ...creen steps to register your product MAIN MENU 12 12 PM General Settings System Settings Safety Security Energy Saving Info Logs Product Serial No Register Product Service Technician Register product...

Страница 5: ...of electric shock Hot surface SECTION 1 SAFETY 1 2 Before you start Read the WARNINGS and PRECAUTIONS Download read the complete Command Centre installation instruction manual and user guide Read and...

Страница 6: ...807041NZ v1 00 03 21 HydroTap G5 UltraCare User guide 6 SECTION 2 Tap operation Touch free Touch Free Wave page 8 BOILING CHILLED CHANGE FILTER SAFETY Classic page 7 HydroTap Mixer Taps page 10...

Страница 7: ...imed dispense Lights BOILING CHILLED CHANGE FILTER SAFETY Dispense options Boiling ready Chilled sparkling ready Filter Use boiling chilled sparkling or ambient lever to dispense your water choice SAF...

Страница 8: ...safety sensors activated water dispensed BLUE Chilled sensor activated water dispensed WHITE Sparkling sensor activated water dispensed PURPLE Lock mode on when tap is idle Flashing RED Sensor activat...

Страница 9: ...e options Sensor range 1 4cm To dispense hold hand within range of the sensors Tap will not operate and light will flash if the sensors are touched or if your hand is too close Boiling Water Chilled A...

Страница 10: ...807041NZ v1 00 03 21 HydroTap G5 UltraCare User guide 10 SECTION 2 Tap operation 2 3 HydroTap Mixer taps Controls mixed water Hot Cold Lift and rotate the lever to dispense mixed warm water...

Страница 11: ...equired screen Here s an example Set the language from the home screen Touch the top left icon to navigate to the main menu Then touch the general settings icon to navigate to the general settings men...

Страница 12: ...e LCD screen visually shows OFF when it is non operational You will hear the sound of an internal click as the HydroTap Command Centre turns ON or OFF When OFF all functions are disabled including hea...

Страница 13: ...maining Sparkling models 12 12 PM 0 CO2 GAS REMAINING REPLACE CO2 GAS When the CO2 cylinder has approximately 20 remaining a warning appears to encourage you to prepare a replacement cylinder SECTION...

Страница 14: ...enu Use the Main menu to configure your HydroTap and access features and settings Touch each icon to access further options MAIN MENU 12 12 PM General Settings System Settings Safety Security Energy S...

Страница 15: ...guide 15 SECTION 3 Command Centre Screen Date and time Touch the text boxes on the screen and then press and to set the current date and time Press the tick to confirm and save Network Connect to Wi F...

Страница 16: ...imes Light Sensor Quiet Mode Advanced Settings System Restart MAIN MENU 12 12 PM General Settings System Settings Safety Security Energy Saving Info Logs Product Serial No Register Product Service Tec...

Страница 17: ...commissioning of a new installation and after every filter change See page 31 for filter change instructions 3 5 1 Filter settings FILTER SETTINGS 12 12 PM Filter Reset Filter Life Filter Flush Tank...

Страница 18: ...hed through the filter This process is automatic and will take 2 minutes Press pause to pause filter flush Approximately 10L of water will flow for 2 minutes The screen will show the filter has been f...

Страница 19: ...When usage exceeds the filter life the tap lights and screen will indicate to change the filter Default life settings are as follows Internal water filter 6 months or 6000L UV C module unit life 24 mo...

Страница 20: ...6 less energy in standby is consumed with a 98 C set point rather than 100 C A warning icon will appear when setting boiling set point temperatures that are subject to pump cavitation COLD HOT SETPOIN...

Страница 21: ...start up the HydroTap self calibrates or go to this menu to recalibrate Calibration will take around 10 minutes External Booster For selected commercial Boiling models an external booster is supplied...

Страница 22: ...in the room is typical for operating conditions The lights on the tap will flash to confirm calibration When the room is darkened below the calibrated light level the tap lights will turn OFF after 30...

Страница 23: ...Hot setpoint must be 98 5 C to disable Periodic Pulse Reduced Cavitation Mode Sends two electric pulses every 5 minutes to the pump This prevents the build up of air bubbles inside the pump to ensure...

Страница 24: ...Demister Mode Enabled default activates the Wave Tap internal heater to prevent its sensors from being affected by condensation from steam Disabled choose this option to conserve a small amount of pow...

Страница 25: ...hot water Hot isolation additional boiling safety 3 slow safety button presses required prior to dispensing Boiling safety lock Enabled default safety button must be touched tapped in order to dispen...

Страница 26: ...code protection to limit access to certain settings Users will be prompted for this passcode when attempting to access settings Create a 4 digit passcode and re enter as prompted The passcode will be...

Страница 27: ...ny attempt to dispense water will bring the HydroTap out of sleep mode Allow sufficient time for the water to reach the set temperature Sleep when Select from It gets dark Not used in 2 hours Both Rec...

Страница 28: ...is highlighted When OFF the HydroTap will stop chilling and heating the drinking water During OFF mode any attempt to dispense water will bring the HydroTap back ON Allow sufficient time for the wate...

Страница 29: ...ate of Reset 3 7 3 Energy Use Track energy usage of your HydroTap by viewing the total energy consumed and the energy consumed since the last energy use reset 12 12 PM SET TIMER Off at On at Mon Tue W...

Страница 30: ...ut System View the system information 3 8 Info logs INFO LOGS 12 12 PM System Faults About System i Filter Logs Recent Faults ABOUT SYSTEM 12 12 PM Title Info Module App revision Serial No Product No...

Страница 31: ...quire changing before the filter change indication is shown You may also need to replace the filter if you notice an increase in chlorine taste or odour Place a cloth or towel under the filter cartrid...

Страница 32: ...e 17 Clean up and dispose of old cartridge and packaging If the HydroTap is switched off for a long period of time e g more than a weekend run water through the chilled water outlet for at least 60 se...

Страница 33: ...4 User maintenance 4 2 Air inlet filter maintenance Remove and clean quarterly Rinse off with tap water Gently dry with a cloth or towel Maintain at least a 50mm air gap in front of the air inlet scre...

Страница 34: ...n wipes may be used to clean around and within the tap spout Do not use strong corrosive spray or abrasive cleaning materials For the Touch Free Wave Tap Do not use strong corrosive spray or abrasive...

Страница 35: ...module up Discard old UV C module Disconnect hose from UV C module and tap tube Discard old hose Unplug the USB connection from the side of the HydroTap The electrical power cable connections may rem...

Страница 36: ...t UV C module usage See page 19 MAINS WATER INLET PRESSURE LIMITING VALVE Unfasten hex nut 1 2 3 4 Remove 2x spade connectors MANIFOLD ASSEMBLY Disconnect hose Remove and discard the safety solenoid I...

Страница 37: ...e tap USB cable 4 Lift out the chilled water tube from which you had removed the hose and discard 5 Insert the new chilled water tube into the tap spout 6 Replace the USB connection and the upper spou...

Страница 38: ...lder Hose and check valve Disposable gloves Chlorine test strips Filter plugs Micropurity Everpure 3M Safety information Refer to the safety data sheet SDS for chemical handling of the CleanOxide tabl...

Страница 39: ...e UV C module and insert the sanitising connector in its place 8 Connect the check valve to the mains water isolation valve 9 Connect one end of the service hose to the check valve and the other end t...

Страница 40: ...sed 19 Reconnect the supply hose from the HydroTap to the mains water isolation valve 20 Remove the filter plug and replace with a new filter cartridge 21 Turn ON the mains water supply 22 Use the LCD...

Страница 41: ...e silicone hose and outlet tube Sanitise system Service 2 95237NZ Service Kit 2 Zenith 1 5Z CF filter Silicone hose and outlet tube 2x CleanOxide tablets 0 5g Safety solenoid UV C module 96863NZ 80928...

Страница 42: ...36 months 3y or 36000 litres Service 1 42 months 3 5y or 42000 litres Filter change 48 months 4y or 48000 litres Service 3 54 months 4 5y or 54000 litres Filter change 60 months 5y or 60000 litres Ser...

Страница 43: ...from installation Type Date Name Sign 108 months 9y or 108 000 litres Service 1 114 months 9 5y or 114 000 litres Filter change 120 months 10y or 120 000 litres Service 2 126 months 10 5y or 126 000 l...

Страница 44: ...1 HydroTap G5 UltraCare User guide 44 Zenith Heaters Limited IRD GST No 95 640 729 18 Kawakawa Place Westgate Auckland 0814 New Zealand Ph 64 9 838 8612 Free Call 0800 558 055 zenithwater co nz AU0269...

Отзывы: