This should only be performed by a qualified tradesperson.
To replace the safety solenoid:
SAFETY
SOLENOID
It may be necessary to disconnect
the hoses and move the Command
Centre to enable access to the rear.
Remove 2 retaining screws and
remove the back panel.
Turn power and water OFF
Next, reset UV-C module usage. See page 19.
MAINS WATER INLET
PRESSURE
LIMITING
VALVE
Unfasten
hex nut
1
2
3
4
Remove 2x spade
connectors
MANIFOLD ASSEMBLY
Disconnect
hose
Remove and discard the safety solenoid.
Install the replacement safety solenoid.
SAFETY
SOLENOID
Fasten hex nut.
Ensure O-ring is
seated.
Connect 2x spade
connectors
Connect hose. Pull
back to test.
Turn ON power and water. Check for and repair any water leaks.
Re-fit the back panel of the Command Centre and reposition it
in place.
MANIFOLD
ASSEMBLY
SECTION 4: User maintenance
4.5 Safety solenoid