Please record all scheduled maintenance in the
maintenance log.
95235NZ In-Field HydroTap Sanitisation (CleanOxide)
kit
is required and can be re-used for all Services.
Type
Kit no.
Service require-
ments:
Filter
change
93706NZ Filter
• Zenith 1.5Z-CF filter
• Change water filter
Service
1
95236NZ Service Kit 1
• Zenith 1.5Z-CF filter
• Silicone hose and
outlet tube
• 2x CleanOxide
tablets, 0.5g
• Change water filter
• Clean air inlet filter
• Replace silicone hose
and outlet tube
• Sanitise system
Service
2
95237NZ Service Kit 2
• Zenith 1.5Z-CF filter
• Silicone hose and
outlet tube
• 2x CleanOxide
tablets, 0.5g
• Safety solenoid
• UV-C module
96863NZ (809283NZ)
• Replace UV-C module
• Replace safety solenoid
• Replace silicone hoses
and outlet tube
• Change water filter
• Clean air inlet filter
• Sanitise system
Service
3
95238NZ Service Kit 3
• Zenith 1.5Z-CF filter
• Silicone hose and
outlet tube
• 2x CleanOxide
tablets, 0.5g
• Safety solenoid
• UV-C module
96863NZ (809283NZ)
• Tap top kit
• Replace tap top
• Replace UV-C module
• Replace safety solenoid
• Replace silicone hoses
and outlet tube
• Change water filter
• Clean air inlet filter
• Sanitise system