807041NZ v1.00 03.21 HydroTap G5 UltraCare User guide
39
Sanitisation procedure
Prepare for sanitisation
1. Ensure all water tanks are full.
2. Turn off mains water supply.
3. DO NOT EMPTY BOILING TANK
- it needs to remain full.
Empty only the chilled tank. Use the service menu on the
LCD screen to view tank levels.
4. Release pressure from the filter flush tap.
5. Remove the filter cartridge. Replace with a filter plug.
6. Disconnect water supply hose from the mains isolation
valve.
Connect sanitising kit
7. Remove the UV-C module, and insert the sanitising
connector in its place.
8. Connect the check valve to the mains water isolation valve.
9. Connect one end of the service hose to the check valve,
and the other end to the isolation valve at the base of the
sanitising canister.
10. Wear all PPE as instructed above.
11. Remove the foil wrap from the CleanOxide tablets. Place
2x 0.5g CleanOxide tablets into the sanitising canister.
12. Connect the mains water supply hose from the HydroTap
to the top of the sanitising canister.
Check valve
Place tablets into
sanitising canister
Isolation valve to
service hose
Door
hanger
Mains water
isolation valve
Sanitising
connector
(in
place of UV-C
module)
SECTION 5: In-field sanitisation