PRELIMINARY INSTRUCTIONS

Please read all these instructions before switching the product on.
Contact an approved repair technician to install, repair and maintain this product.
If the power cable is damaged, replacement must be carried out by an authorised technician.
Installation should be carried out in accordance with national electricity regulations in force and only 
by an authorised technician.
This apparatus should not be considered as a toy by your children.
We  advise  you  not  to  leave  children  or  handicapped  persons  near  this  apparatus  without 
supervision.
Please  make  a  note  of  the  product  model,  the  product  series  number  and  the  name  of  the  retailer 
and date of purchase and installation. This information will be needed in the event of any exchange 
with the technical support team.
This product must be disposed of in accordance with the procedure imposed by European standards 
EN50419: 2005 (directive 2002/96/EC) concerning electronic waste.

CONCERNED RANGE

Residential – Easy to Install

R410A INVERTER

SCI – SPI – SQI – CSI

IMHI – IMMI – ICMI - IKMI

R410A

SCR – SCF - SQR

Light Commercial

R410A INVERTER

ASI – GSI – KSI

R410A

ASR – GSR - KSRxxB

ASF – GSF – KSFxxB

Содержание Air Conditioner

Страница 1: ...110413 NUT SPLIT MULTI R410A EN User s Manual AIR SOURCE HEAT PUMP Air Conditioner ON OFF INVERTER DC SPLIT SYSTEM MULTISPLIT INVERTER DC...

Страница 2: ...vise you not to leave children or handicapped persons near this apparatus without supervision Please make a note of the product model the product series number and the name of the retailer and date of...

Страница 3: ...gramming TIMER R06 R05 14 3 5 7 Override MANUAL AUTO COOL 15 4 DISPLAY 16 4 1 Display of PCB 16 4 1 1 On model cassette18K duct 16 4 1 2 On model Cassette KSI KSF R Wall split SCI SCF R SQR SQI 16 4 1...

Страница 4: ...taken in terms of use to avoid the most serious risks to persons the product and its environment Connect to an electrical power supply and ensure that the appliance is plugged into the socket correctl...

Страница 5: ...e appliance with the windows open may lead to the appearance of condensation and damage surrounding furnishings A faulty plug may lead to electric shocks and bodily harm Failure to do so may cause the...

Страница 6: ...pe R51 Type R06 Type R05 3 2 Display PCB 3 2 1 Location of the display PCB A receiver located on a display panel on the front of the indoor unit products of the wall floor ceiling cassette and console...

Страница 7: ...x DUCT model I Infrared receptor Wall split models SHI SHR SHF SHI IMHI The infrared receptor is located on the display panel on the front of the indoor unit Wall split models SPI SCI SCR SCF SQI SQR...

Страница 8: ...t use liquid detergent to clean the remote control Keep the remote control away from excessive temperatures or radiation zones Ensure that no remote control for any other appliance can interfere with...

Страница 9: ...ng motion or to fix the position of the air outlet around the initial position by using the AIR DIRECTION button see below 5 CLEAN AIR This function allows the ION PLASMA filters operating and purifyi...

Страница 10: ...to programme a duration after which time the product stops 14 LOCK This locks the remote control settings Pressing this button a second time deletes this function 15 TURBO Wall mounted product POWERFU...

Страница 11: ...oduct is programmed to stop at a certain time TIMER ON OFF is indicated if the start and stop times are both programmed If there is no indication then no start or stop time has been programmed 5 Fan s...

Страница 12: ...he indoor unit display panel will stop flashing The product automatically selects the most suitable operating mode among the operating modes available COOL cooling HEAT heating FAN fan and DRY dehumid...

Страница 13: ...veral times the length of time before starting will increase in increments of 30 mins until 10h then in increments of 1hour until 24h A half second after depressing the TIMER ON button once the desire...

Страница 14: ...he hour remain displayed on the remote control indicating that a start programme is active TIMER programming indicator of the indoor unit display panel is shown Note The TIMER function is only active...

Страница 15: ...he front panel and it is labelled AUTO COOL Using the override button Press once the product will start in automatic AUTO mode the operational indicator OPERATION will be displayed the remote control...

Страница 16: ...AUTO 2 Hot start or DEFROST indicator heating mode 3 Set temperature display and default temperature on some models 4 Operational indicator OPERATION 5 Programming indicator TIMER 4 1 4 Sur mod les m...

Страница 17: ...dify DRY mode During the summer months if possible close shutters on windows to avoid direct sunlight in the room Do not install objects that may obstruct the air inlet or outlets of the indoor and ou...

Страница 18: ...he fan blades or the horizontal mechanical vent and also not to damage the manual vents 5 3 Cassette model The automatic air outlet vents and sweeping vents must be carefully positioned A mechanical v...

Страница 19: ...ed to direct the air flow left or right Note Do not move motorised vents manually on the indoor unit Do not operate the indoor unit with the motorised vent in closed position or only slightly open los...

Страница 20: ...l products or any products containing polishing powders 6 1 Dismounting and cleaning the filter 6 1 1 Wall mounted model Lift up the Unclip the filters Remove front panel from their fixings the filter...

Страница 21: ...e models 6 2 Cleaning the filters Clean the filters with a vacuum cleaner fig 1 or with tepid soapy water fig 2 Rinse filters with clear water and dry them in a temperate ambience do not dry in the su...

Страница 22: ...on disappears from the remote control There is no BEEP sound from the receiver to indicate that a signal is received when the ON OFF button is pressed Ensure that the remote control batteries are not...

Страница 23: ...ded in this documentation can be modified without prior notice Information that was not available when this documentation went to press may be integrated later The most recent updates can be consulted...

Страница 24: ...24 122 avenue des Pyr n es BP82 33883 Villenave d Ornon Cedex France WEB www zhendre com...

Отзывы: