EN - 14
2.7.2 P menus for the user
Menu P1
¨
Status of programmes
Status
Sub-menu
Description
Activated
P11
Is menu 21 currently active?
Yes (1) / No (0)
P12
Is menu 22 currently active?
Yes (1) / No (0)
P13
Is menu 23 currently active?
Yes (1) / No (0)
P14
Is menu 24 currently active?
Yes (1) / No (0)
P15
Is menu 25 currently active?
Yes (1) / No (0)
P16
Is menu 26 currently active?
Yes (1) / No (0)
Menu P2
¨
Setting time delays
Time delay values
Sub-menu
Description
Minimum
Maximum
General
Reset
P21
(Optional)
Note:
Only applies to systems fitted with a
corded switch and a second switch in
the bathroom.
Delay timer for the bathroom switch (to switch to high
position).
■
'x' minutes after operating the bathroom switch, the
ComfoAir switches to the high setting.
- Low voltage input
0 Min.
15 Min.
0 Min.
P22
(Optional)
Note:
Only applies to systems fitted with a
corded switch and a second switch in
the bathroom.
Overrun timer for the bathroom switch (to switch to
normal position).
■
'x' minutes after operating the bathroom switch, the
ComfoAir switches back to the normal setting.
- Low voltage input
0 Min.
120 Min.
30 Min.
P23
(Optional)
Note:
Only applies to systems fitted with a
hardwired 3-position switch.
Overrun timer for ventilation position 3 (using a wired
3-position switch).
■
If ventilation setting 3 (high) is switched on briefly (<
3 sec), the ComfoAir will switch to the high setting
for 'x' minutes and then automatically returns to the
normal setting.
If any 3-position switch is operated during this lagging
time the ComfoAir will instantly revert to the ventilation
position as set at that time.
0 Min.
120 Min.
0 Min.
P24
Filter warning
■
'x' weeks after cleaning the filters the "filter dirty"
alert will reappear.
10 weeks
26 weeks
16 weeks
P25
Note:
Only applies to systems fitted with an
RF switch.
Overrun timer for ventilation setting 3 (using "
").
■
After pressing "
" briefly (< 2 sec.), the ComfoAir
will switch to the high setting for ‘x’ minutes and then
automatically returns to the normal setting.
If any 3-position switch is operated during this lagging
time the ComfoAir will instantly revert to the ventilation
position as set at that time.
1 Min.
20 Min.
10 Min.
P26
Note:
Only applies to systems fitted with an
RF switch.
Overrun timer for ventilation setting 3 " using
".
■
After pressing "
" continuously (> 2 sec.), the
ComfoAir will switch to the high setting for ‘x’ minutes
and then automatically returns to the normal setting.
If any 3-position switch is operated during this lagging
time the ComfoAir will instantly revert to the ventilation
position as set at that time.
1 Min.
120 Min.
30 Min.
P27
N/A
0 Min.
120 Min.
30 Min.
Menu P9
¨
Status of programmes (from menu P5 and P6 additional programmes)
Status
Sub-menu
Description
Activated
P90
Open fire programme active?
Yes (1) / No (0)
P91
Bypass Open?
Yes (1) / No (0)
P94
Analogue input (0-10V) active?
Yes (1) / No (0)
P95
Frost protection or Preheater active?
Yes (1) / No (0)
P97
Enthalpy programme active?
Yes (1) / No (0)