ZyPer4K-M
User Manual Revision 2.5
Ventilation
Ambient environmental temperature and humidity shall not exceed that specified in the Detailed
Specifications portion of this document.
Ambient temperature in this case refers to the temperature of air entering the device through the
ventilation grille. Care should be taken to not enclose the device or deploy in an fashion where
airflow loops or local “hot spots” can cause the inlet air to rise above the specified limit for
normal operation.
In general 25mm (
≈
1inch) of clearance should be provided around the ventilation openings
unless an external air mover insures that the inlet temperature is at or below the specified limit.
If the equipment is mounted in an enclosed cabinet, it is the job of the installer to insure that
within the cabinet or enclosure the ZyPer4K-M equipment does not experience local
temperatures in excess of that specified in the Detailed Specifications portion of this document.
Water and moisture
Never expose the ZyPer4K unit to direct rain, moisture, or excessively high humidity.
Never use the device near water - e.g. near a bathtub, basin, pool, sink, or in a wet basement.
Clean only in accordance with the instructions in this manual.
Operational and Overall LifeSpan of Equipment
Equipment is capable of continuous operation providing the environmental and operating
parameters are satisfied.
Equipment may be stored in unpowered state providing the specified storage considerations are
met. There are no minimum ON or OFF requirements.
The powered and operational “Mean-Time-Between-Failures” exceeds 5 years.
The overall physical lifespan (non-operation life) of the Equipment is dictated by the certified
and usable lifespan of the underlying physical materials and components. It will exceed 25
years providing the environmental specifications are met for both storage and operation.
User Manual
Page
of
27
53