background image

ZyPer4K-M

User Manual Revision 2.5

The ZyPer4K unit is fairly tolerant to cleaning with moistened cleaning cloths, but the unit 
is not fluid tight.  Care should be taken to not spray cleaner directly on to the unit or into 
the vents to avoid liquid ingress and damage to the internal electronics.

CAUTION:

 Do not apply or spray liquid directly on 

to the unit’s exterior as excess liquid may cause 
damage to internal electronics. Apply the liquid to 
the cleaning cloth first.

 

3. Repeat with water-moistened cloth only. 

4. Wipe with a dry cloth

5. Air vents shall be checked to make sure that they are free of accumulated lint or blockages.

Should the air vents appear clogged use a vacuum cleaner with a soft-bristle brush 
attachment to loosen and draw the debris out of the vents and away from the unit.

Do not loosen and blow the debris in to the unit as internal buildup of debris will degrade 
the ability of the unit to cool itself and reliability may be adversely affected.

Do not apply power if there is any evidence of fluid in the interior of the unit. 

ZyPerMP Specific Cleaning Procedure 

The ZyPerMP control unit is not designed to be placed in an environment 
that would subject it to impurities that require as frequent cleaning as the 
encoder and decoder units.  Should the ZyPerMP unit need cleaning, the 
same procedures apply as enumerated above, only a very sparing amount 
of cleaner should be applied to the cleaning cloth.

User Manual

Page 

 of 

21

53

Содержание ZyPer4K-M

Страница 1: ...ZyPer4K M GENERATION 3 IP VIDEO DISTRIBUTION SYSTEM MEDICAL GRADE User Manual REVISION 2 5...

Страница 2: ...fected About ZeeVee ZeeVee is the leading manufacturer of high quality encoder modulator decoder products for video distribution over any type of transmission media be it RF coax fiber or copper ether...

Страница 3: ...2 Optional Ports 10G Ethernet 14 Optional Ports USB 15 Setting Up ZyPer4K in a Point to Point Environment 16 Setting up ZyPer4K in Many to Many Environment 17 General Safety and Care Instructions 18 S...

Страница 4: ...Power Off 36 Decommissioning 36 Responsibility and Stewardship 37 Reduction of Hazardous Substances RoHS 37 Waste Electrical and Electronic Equipment 37 FCC Compliance Statement 39 EMC Information 40...

Страница 5: ...document to refer to the ZyPer4K Family of Medical Grade Video Distribution Equipment offered by ZeeVee A minimal system consists of Video Source ZyPer4K M Encoder device Cable or Fiber ZyPer4K M Deco...

Страница 6: ...c Other ports on the Encoder devices are for the carriage of USB RS232 and audio data as well as a 1Gbit second utility port for general purpose connectivity of devices to the 10G bulk data infrastruc...

Страница 7: ...ion Rating for the Decoder devices is IPX0S Common Interfaces on all Decoders Power Input 12VDC RS232 Input Output 1Gbit sec Utility Ethernet Port Analog Audio Output Infrared Input Infrared Output HD...

Страница 8: ...pecial case and self configure appropriately Any installation beyond simple point to point link extension like applications require a ZyPerMP The purpose of the Management Platform is to interface use...

Страница 9: ...are two different sizes of the ZyPer4K M Encoder unit enclosure The USB option does not affect the enclosure size The type of bulk media 10G Fiber or 10G Copper does not affect the enclosure size Inp...

Страница 10: ...Network B 10 100 1000Base T Ethernet port Used for general purpose device attachment to network Traffic will be switched on to media network Ground Lug C For equipotential referencing of the box this...

Страница 11: ...g processed Audio D Audio Input Jack Expects line level stereo audio on 3 5mm jack as indicated below note 1 IR OUT E Infrared Commands information passed back FROM decoders as configured by Maestro Z...

Страница 12: ...regardless of the enclosure size Port Name Index Definition 10G Fiber A1 10 Gigabit Ethernet Connection Uses standard 10G pluggable devices SFP devices 10G Copper A2 10G Ethernet over Cat6a or better...

Страница 13: ...are available with or without a USB port Port Name Index Definition USB A USB 2 0 Type B port for use USB option is ordered and installed Configuration and routing of USB handled by the Maestro Z con...

Страница 14: ...DI Input supports up to 1080P60 w up to 8 channels of embedded audio HDSDI Loop C Copy of HDSDI Input port retimed and reamplified and presented for downstream devices LOCK LED D Blue LED illuminated...

Страница 15: ...ut carrying stereo L R line level audio for transport Analog Breakout Following connections supported YPrPb resolutions up to 1080P60 CVBS PAL and NTSC resolutions S PDIF digital audio input Analog L...

Страница 16: ...e following ports are common to all decoders regardless of the options or enclosure variant The following ports are common to all decoders regardless of the interface options Input Function Box Size H...

Страница 17: ...n unit is powered LED VID C LED Illuminated when active video is being processed Audio D Audio Output Jack Drives line level stereo audio on 3 5mm jack IR OUT E Infrared Commands information passed FR...

Страница 18: ...on 2 5 Optional Ports 10G Ethernet Port Name Index Definition 10G Fiber A1 10 Gigabit Ethernet Connection Uses standard 10G SFP devices 10G Copper A2 10G Ethernet over Cat6a or better cabling RJ45 Use...

Страница 19: ...vity Shown to the left is a unit with the USB option top and without the USB option bottom installed This is a build time option and is not retrofittable to the product Port Name Index Definition USB...

Страница 20: ...ement software See the ZyPer4K Management Platform User Manual for more information 1 Connect HDMI cable from active source to Encoder HDMI In port Ensure Encoder is plugged in and pwr LED light illum...

Страница 21: ...hrough the ZyPer4K management software To set up ZyPer4K in a many to many environment you have to Install ZyPer4K management software Connect all Encoders and Decoders to the 10Gb network switch Swit...

Страница 22: ...the obsolete outlet Power cord must be accessible to allow for the removal of the power from the unit Protect the power cord from being walked on or pinched particularly at plugs convenience receptacl...

Страница 23: ...ronmentally induced over stress conditions and is an integral part of the compliant system WARNING Do not open the box or in any way expose the internal circuitry WARNING There are no user serviceable...

Страница 24: ...upplied rubber plugs or a piece of tape to prevent cleaner from entering and possibly affecting operation 2 Clean the exterior of the unit with a soft cotton cloth that has been lightly moistened with...

Страница 25: ...ages Should the air vents appear clogged use a vacuum cleaner with a soft bristle brush attachment to loosen and draw the debris out of the vents and away from the unit Do not loosen and blow the debr...

Страница 26: ...customer control system for sophisticated presentation and management of the information flow and direction ZyPer4K M Products are non patient care equipment Equipment may not be used with life suppor...

Страница 27: ...ipment using best industry practices Prior to installation party performing the installation shall read and understand the ZyPer Get Going Guide can be downloaded from ZeeVee website Familiarity and a...

Страница 28: ...at the units are rigidly held in place and will not be subject to impact and there is no possibility of toppling Do not stack any other equipment or devices on top of the unit weighing more than 3Kg a...

Страница 29: ...ss and slot cutouts allow for great flexibility in mounting When using the L Brackets first remove the screws and rubber feet on the bottom of the unit Retain the screws as they will be used to affix...

Страница 30: ...zed The recommended sequence of hardware would be Drywall anchor Flat Washer ZyPer4K M L Bracket Flat Washer Screw or Bolt Sheet Metal Shelf or Equipment 6 up to 10 thread forming or thread cutting ma...

Страница 31: ...experience local temperatures in excess of that specified in the Detailed Specifications portion of this document Water and moisture Never expose the ZyPer4K unit to direct rain moisture or excessivel...

Страница 32: ...nk shall be connected to the switching gear on the far end of the cable After the full data connection set is made power applied and the unit operational the TX and RX lights will blink rapidly back a...

Страница 33: ...oder Decoders support only a single type of output HDMI 2 0 supporting HDCP 2 2 Connect an appropriately rated HDMI cable from the decoder unit to the display device When powered the Decoder will imme...

Страница 34: ...er supply shall be powered from the appropriately rated AC mains voltage which allows for a wide range of input generally from 100VAC through 240VAC Only use a power cord with an appropriately rated p...

Страница 35: ...quivalent 18 AWG min rated 250 V min provided with a hospital grade type plug 5 15P configuration for 120V application or 6 15P for 240V application AC DC converter inlet side of AC cord shall be of t...

Страница 36: ...The Operator then needs to consult the ZyPer Management Platform Quick Start Guide and or the ZyPer Management Platform User Manual Logical connections between Encoders Decoders and display configurat...

Страница 37: ...a universal stud on the rear of the unit near the power connector for this purpose Two nuts are also provided to allow for a locking connection This stud is sized and threaded for 8 hardware This is...

Страница 38: ...he locking feature insures the ring lug will not loosen over time given environmental handling or vibration The Equipotential Stud is an 8 32 threaded connection Employ a ring lug of the proper diamet...

Страница 39: ...eo cables should employ an EMI bead at the source and terminus to contain and manage EMI energy from the attached units User Manual Page of 35 53 Material Limit Lead and its compounds Pb 1000 ppm Hexa...

Страница 40: ...t has been powered off using one of the above methods verify the powered off state by insuring that the PWR LED is not illuminated Decommissioning To decommission a unit first power the unit using met...

Страница 41: ...Vee products do not contain the listed materials Since we do not expect these materials to be present we do not specifically run a complete analysis on all finished goods excepting for periodically au...

Страница 42: ...e recycling of this product please contact your local waste disposal authorities or local municipal waste disposal service For specific questions related to WEEE compliance of ZeeVee products contact...

Страница 43: ...more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and the receiver 3 Connect the equipment to an outlet on a circuit differen...

Страница 44: ...ould only be connected to HDMI cables rated for 4K operation at the desired resolutions e g HDSDI cables should be of the appropriated impedance and within the length restrictions of the greater HDSDI...

Страница 45: ...er quality typical for commercial or medical facility Surge 61000 4 5 1 kV line s to line s 2 kV line s to earth PASS Expected power quality typical for commercial or medical facility Conducted RF 610...

Страница 46: ...put Connector Type A receptacle female HDMI Resolutions Supports all major VESA resolutions and variations including 640x480 p i 720x576 25Hz 50Hz p i 800x600 p 1024x768 p 1280x720 p i 1280x1024 p 136...

Страница 47: ...the factory Type Parameter DisplayPort Option Single DisplayPort receptacle support v1 3 of the DisplayPort standard direction Input resolutions Same complete set of resolutions as supported by the re...

Страница 48: ...ion Single Input port supporting Single Link 3G SDI SMPTE424M input LoopThrough Retimed re amplified direct copy of the input signal provided on the Loop port for downstream chaining of the 3G SDI inp...

Страница 49: ...n DIN connector Supports 480i and 576i resolutions NTSC and PAL YPrPb Standard Component Video input provided through Red Green and Blue RCA connectors spawned by the ZeeVee Hydra Cable connected to t...

Страница 50: ...level L R analog stereo input through 3 5mm plug spawned by the VGA version of the ZeeVee Hydra cable connected to the 13 Pin DIN jack Digital Audio When S PDIF connection of the ZeeVee Hydra analog...

Страница 51: ...ZyPer4K M User Manual Revision 2 5 User Manual Page of 47 53...

Страница 52: ...ZyPer4K M User Manual Revision 2 5 User Manual Page of 48 53...

Страница 53: ...er Ethernet Only one of those options is supported at a given time only one of the above may be installed at a given time Type Encoder Decoder Parameter Fiber Ethernet Single 10GBASE F xx receptacle s...

Страница 54: ...ndard 9 pin Female DCE connector Communication up to 115 2K baud USB A 2 optional 2 x Standard USB 2 0 Type A port USB B optional 1x Standard USB2 0 Type B port Analog Audio 3 5mm L R analog audio jac...

Страница 55: ...erall width if both mounting ears are installed Weight 880g Decoder Encoder with no extended input option 1070g Encoder with extended input option Operating Temperature 0 C to 45 C 32 F to 113 F Non O...

Страница 56: ...edical certification submission package SDM 2 0 June 14 2017 Updates based on ISO14971 review Updates for enhanced EP stud addition SDM 2 1 June 20 2017 Updates based on internal review SDM 2 2 June26...

Страница 57: ...license component utilized ZeeVee represents that normal usage of the product in a typical customer installation is fully within the granted rights and privileges of any licensed component Visit www z...

Отзывы: