8.3.2 PYLONTECH BATTERY SETTINGS ON INVERTER - 2 Wi-Fi/USB SC500 & SC1000 BATTERY TOWERS
Set the battery channels in the inverter according to the configuration of the battery towers.
Configure the
inverter channels:
Basic settings
Channel configuration:
When connecting
2 Pylontech towers
:
o
Input channel 1 – BAT input 1;
o
Input channel 2 – BAT input 1.
To set the
battery parameters
:
Advanced settings
0715
Battery parameters:
When connecting
2 Pylontech towers
:
- Battery 1:
o
Type: Pylon ; Address: 01; Maximum charge/discharge current: 50 A; Depth of
discharge: 80%.
BATTERY 1
1.Battery type
Pylon
2.Battery address
01
3.Maximum charge (A)
50.00A
4.Maximum discharge (A)
50.00A
5.Depth of Discharge
80%
6.Save
NOTE:
The first time the inverter is switched on, error code ID044 (PvConfigError) may appear in
the current event list for about 5/10 minutes. Do not switch off or restart the inverter as this
behaviour is caused by the BMS configuration. After this waiting period, the system will start
operating normally.