NOTE: with this configuration, the system becomes an IT system during a blackout.
2. Advanced settings
1. Battery parameters
5. Depth of discharge
✔
1.Basic settings
7. Select EPS mode
1.EPS control mode
1.Enable EPS mode
✔
1.Disable EPS mode
To enable the EPS (OFF-GRID) mode:
1. The EPS mode must be enabled from the display.
2. The following parameters must be set from the Depth of Discharge
menu.
In the event of a power
blackout
, the alternating voltage supplied by the mains will be lost. This condition will
cause the internal contacts of the hybrid inverter to switch over which, once the set activation time has
expired, will continue to supply an alternating voltage of 400V to the LOAD output, supplying power only to
the critical loads according to the availability of the batteries and PV system.
18.4 EPS MODE (OFF GRID) - MENU ENABLING
400V
0V