9.2.1 5K3 WECO BATTERY CONNECTION – 2 BATTERY TOWERS
HV-BOX 1
•
Communication address:
00000010
•
Connect the communication cable between
the two
HV-BOXES
to CAN2-B port.
Communication connections between the two HV-BOXES
HV-BOX 2
•
Communication address:
10000000
•
Connect the communication cable between
the two
HV-BOXES
to CAN2-B port.
Power connections between the two HV-BOXES and inverter
BAT1 INPUT BAT2 INPUT
+
-
+
-
INVERTER
HV-BOX 1
HV-BOX 2