9.5 MIXED CONNECTION BETWEEN 5K3 WECO AND 5K3 XP WECO BATTERIES
Batteries
are connected
IN SERIES
to each other:
•
Negative input (-) of
battery 1
connected to positive input (+) of
battery 2
.
•
Negative input (-) of
battery 2
connected to positive input (+) of
battery 3
.
•
…..
•
Negative input (-) of
battery N-1
(second-last) connected to positive input (+) of
battery N
(last).
The
HV-BOX
is connected in parallel to the series consisting of the
batteries
:
•
Negative input (-) of the
HV-BOX
connected to negative input (-) of
battery N
(last) in the series.
•
Positive input (+) of the
HV-BOX
connected to positive input (+) of
battery 1
.
Connect each device to the ground system.
Communication connections:
•
CAN1-B of
XP HV-BOX
to CAN-A of
battery 1.
•
CAN-B of
battery 1 (5k3 XP)
to CAN-A of
battery 2 (5k3 XP)
.
•
…
•
CAN-B of
battery 6 (5k3 XP)
to CAN-A of
battery 7 (5k3 XP)
.
•
CAN-B of
battery 7 (5k3 XP)
to CAN-A of
battery 8 (5k3)
.
•
LINK-B of
battery 7 (5k3)
to LINK-A of
battery 8 (5k3)
.
•
CAN-B of
battery 8 (5k3)
to CAN-A of
battery 9 (5k3)
.
•
LINK-B of
battery 8 (5k3)
to LINK-A of
battery 9 (5k3)
.
•
…
•
CAN-B of
battery N-1
(second-last 5k3) to CAN-A of
battery N
(last 5k3).
•
LINK-B of
battery N-1
(second-last 5k3) to LINK-A of
battery N
(last 5k3).
Power and communication connections between batteries and HV-BOX
For a new system, we do not recommend installing a mixed solution with mixed 5K3 and 5K3XP batteries.
When using 5k3 and 5k3XP batteries, it is mandatory to:
- Install an
XP HV-BOX
;
- Install
at least one 5k3XP battery
(the 5k3 XP batteries must be installed just below the XP HV BOX, while the 5k3 batteries must be
inserted last).
Channel configuration:
Configure the inverter channels according to the number of HV-BOXES connected to the inverter (see previous paragraphs).