7.10 Description of Alarm menu
The microprocessor in the controller records the last five Alarms that have
occurred. Items remembered relative to each Alarm are: the code of the alarm,
the number of times the particular Alarm occurred and the Hour Meter count. This
function permits deeper diagnosis of problems as the recent history can now be
accessed.
Flow Chart showing how to use the ALARMS function via the Digital Console:
1) Opening Zapi Menu
DISP E ZP V0.0
48V 0A 00000
2) Press ENTER to go into the MAIN MENU
' % '
' ' '
3) The Display will show:
MAIN MENU
PARAMETER CHANGE
4) Press ROLL UP or ROLL DOWN until
ALARMS menu appears on the display
% ' '
% ' '
5) The Display will show:
MAIN MENU
ALARMS
6) Press ENTER to go into the ALARMS menu
' % '
' ' '
7) The display will show the most recent alarm
CODE
00005h #02 20°C
8) Each press of ROLL UP button brings up
following alarms. Pressing ROLL DOWN
returns to the most recent
% ' '
% ' '
9) If an alarm has not occurred, the display will
show: NONE
NONE
00000h #00 0°C
10) When you have finished looking at the alarms,
press OUT to exit the ALARMS menu
' ' '
' % '
11) The Display will ask: “CLEAR LOGBOOK?”
Press ENTER for Yes, or OUT for No
CLEAR LOGBOOK?
YES=ENTER NO=OUT
12) Press OUT again and return to Opening Zapi
Menu
' ' '
' % '