Page - 72/81
AFCZP0BC- COMBIACX & ACEX - User Manual
12.3 Warnings overview
Error code
Description
Effect
Machine status
when the test is
done
Restart
procedure
Slip profile -
MDI CAN 99
Error on the parameters of the slip
profile setting.
Traction is stopped
start-up, stand-by Traction
request
Forw+backwa
rd - MDI CAN
80
The travel demands are active in both
directions at the same time
Traction is stopped
start-up, stand-by,
traction
Traction
request
Incorrect start -
MDI CAN 79
Incorrect starting sequence
Traction is stopped
start-up, stand-by Traction
request
Vacc not ok -
MDI CAN 78
The acceleretor value is higher than
the minimum value recorded, and the
direction/enable switches are opened.
Traction is stopped
start-up, stand-by,
traction
Traction
request
Th. Protection -
MDI CAN 62
The controller has reached the
thermal cutback temperature 85°C
Traction controller
reduces the maximum
current linearly from
Imax (85°C) down to
0A (105°C)
continuous
Battery low
Battery is <= 10% when the
parameter BATTERY CHECK is set
>0
The maximum current
is reduced to half and
speed is reduced (if
CHECK OPTION = 1)
continuous
Eeprom ko -
MDI CAN 71
Error is detected in eeprom or in
eeprom management
Controller works using
Deafult parameters
continuous
Motor
temperat -
MDI CAN 65
Traction motor temperature sensor is
opened (if digital) or has overtaken
the threshold of 150°C (if analog)
The maximum current
is reduced to half and
speed is reduced
continuous
Thermic sens
ko - MDI CAN
61
The output of the controller thermal
sensor is out of range.
The maximum current
is reduced to half and
speed is reduced
continuous
Check up
needed
Maintenance time is reached
Data
acquisition
Maximum current adjustment
procedure is in progress (NOTE: this
procedure has to be done only by
Zapi test department)
Traction is stopped
stand-by
Traction
request
Tiller open -
MDI CAN 51
The truck is in stby with tiller switch
opened for more than 30s
LC opens
standby
Valve or pump
or traction
request
Current gain -
MDI CAN 92
The Maximum current gain
parameters are the default values,
which means the maximum current
adjustment procedure has not been
carried out yet
Controller works, but
with low maximum
current
start-up, stanby
Waiting for
node - MDI
CAN 68
A Canbus network node is in alarm
condition. uC is waiting for it to
resolve its error condition.
continuous
Содержание COMBIACX
Страница 27: ...AFCZP0BC COMBIACX ACEX User Manual Page 27 81 8 DRAWINGS 8 1 Mechanical drawing COMBIACX...
Страница 28: ...Page 28 81 AFCZP0BC COMBIACX ACEX User Manual 8 2 Mechanical drawing ACEX...
Страница 29: ...AFCZP0BC COMBIACX ACEX User Manual Page 29 81 8 3 Connection drawing COMBIACX...
Страница 30: ...Page 30 81 AFCZP0BC COMBIACX ACEX User Manual 8 4 Connection drawing ACEX...
Страница 35: ...AFCZP0BC COMBIACX ACEX User Manual Page 35 81 10 3Description of the console menu 10 3 1 COMBIACX ACEX Menu...