38) MAX EVP
From 0 to 100. This parameter determines the maximum current applied to the
EVP when the position of the potentiometer is at the maximum. This parameter
also determines the current value when the EVP is programmed like an
ON/OFF valve.
39) EVP OPEN DELAY
Seconds. It determines the acceleration ramp on EVP.
The parameter sets the time needed to increase the current to the maximum
possible value.
40) EVP CLOSE DELAY
Seconds. It determines the deceleration ramp on EVP.
The parameter sets the time needed to decrease the current from the maximum
possible value to zero.