AFCZP0BC – COMBIACX & ACEX - User Manual
Page - 51/81
10) MOTOR TEMPERATURE
°C value. This is the temperature of the motor windings picked up with an
analog sensor inside the motor. Normally this sensor is a PTC Philips KTY84-
130 or a KTY83. It depends on SET MOT. TEMP. option.
11) PUMP CURRENT
Ampere. It is the continuous current in the pump motor.
12) PUMP VMN
It is the voltage applied to the pump motor. Expressed in percentage of the
maximum voltage.
13) ACCELERATOR
From 0.0V to 5.0V. The voltage on the wiper of the accelerator (CPOT on
CNC#4) is halved inside the controller and then recorded on this reading. That
means the actual wiper voltage is in the range 0 to 10V meanwhile the
corresponding ACCELERATOR reading is in the range 0.0 to 5.0Vdc.
14) LIFTING CONTROL
From 0.0 to 5.0V. The voltage on the wiper of the accelerator (CPOTLIFT on
CNC#9) is halved inside the controller and then recorded on this reading.That
means the actual wiper voltage is in the range 0 to 10V meanwhile the
corresponding ACCELERATOR reading is in the range 0.0 to 5.0Vdc
15) DI0/TILLER SWITCH
ON/OFF. This is the level of the digital input CNC#6 for the Tiller input.
-
ON +VB = When it is closed to a battery (key) voltage, the Tiller input is
Active.
-
OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the Tiller input is not active.
16) DI1/BELLY SWITCH
ON/OFF. This is the level of the digital input CNC#2 ( belly button):
-
ON +VB = When it is closed to a battery (key) voltage, the request of the
Belly (to stop the movement) is active.
-
OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the Belly request is not active.
17) DI2/ H&S CUTBACK
ON/OFF. This is the level of the digital input CNC#7 for the Hard & Soft request.
With the H&S service is possible to turn the truck moving (at reduced speed)
only by acting the H&S switch, and the accelerator, without to let down the tiller :
-
ON +VB = When it is closed to a battery (key) voltage, the H&S request is
Active.
-
OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the H&S request is not active.
18) DI3/FORWARD SWITCH
ON/OFF. This is the level of the digital input CNB#4 for the forward travel
demand:
-
ON +VB = When it is closed to a battery (key) voltage, the Forward Travel
demand is Active.
-
OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the Forward Travel demand is not active.
Содержание COMBIACX
Страница 27: ...AFCZP0BC COMBIACX ACEX User Manual Page 27 81 8 DRAWINGS 8 1 Mechanical drawing COMBIACX...
Страница 28: ...Page 28 81 AFCZP0BC COMBIACX ACEX User Manual 8 2 Mechanical drawing ACEX...
Страница 29: ...AFCZP0BC COMBIACX ACEX User Manual Page 29 81 8 3 Connection drawing COMBIACX...
Страница 30: ...Page 30 81 AFCZP0BC COMBIACX ACEX User Manual 8 4 Connection drawing ACEX...
Страница 35: ...AFCZP0BC COMBIACX ACEX User Manual Page 35 81 10 3Description of the console menu 10 3 1 COMBIACX ACEX Menu...