A10 GND
This is the ground of the logic board.
A11 DI6
Input of the switch DI6. The input is activated when it is
connected to +Batt. The default function is the controller
“
LOWER
” enable input.
A12 DI8
Input of the switch DI8. The input is activated when it is
connected to +Batt. The default function is the controller
“
1ST
” input: the pump motor turn at a defined speed.
A13 DI10
Input of the switch DI10. The input is activated when it is
connected to +Batt. The default function is the controller
“
2ND
” input: the pump motor turn at a defined speed.
A14 DI12
Input of the switch DI12. The input is activated when the
external switch is opened to ground. The default function
is the controller “
CUTBACK2
” input, opening the switch
truck speed is reduced. In the Sense Coil version this
input is connected to the AC motor sense coil.
6.1.2 CNB external connector
B1
PEB
This pin outputs the positive supply (equal to +Batt) of the
electromechanical brake coil. Depending on hardware
configuration this pin can be controlled by the
microcontroller or tied to the B2 input or to the C6 input.
See connection drawing for more details.
B2
PEV
Connect the positive supply of all electrovalves (EV1,
EV2, EV3, LOWER EVP, HORN OUT) to this pin. Take
the positive supply immediately after main contactor.
B3
NEVP
Output of the lower proportional electrovalve driver
(driving to –Batt). Built-in freewheeling diode to B2.
B4
DI3
Input of the switch DI3. The input is activated when it is
connected to +Batt. The default function is the controller
“
FORWARD
” request input, closing this input truck moves
in forward direction.
B5
NEB
Electro mechanic brake coil driver output; PWM
controlled; 2.5A maximum continuous current (driving to –
Batt). Built-in freewheeling diode to B1.
B6
NLC
Min Contactor coil driver output; PWM controlled; 1A
maximum continuous current (driving to –Batt). Built-in
freewheeling diode.
B7
HORN
Negative of the protected horn electrovalve driver (driving
to –Batt). Built-in freewheeling diode to B2.
B8
DI4
Input of the switch DI4. The input is activated when it is
connected to +Batt. The default function is the controller
“
REV
” request input, closing this input truck moves in
backward direction.
6.1.3 CNC external connector
C1
+KEY
Input of the key switch signal.
C2
DI1
Input of the switch DI1. The input is activated when it is
connected to +Batt. The default function is the controller
“
BELLY
” input, closing the switch quick inversion function
is activated.
C3
NPOT
Potentiometers negative reference (GND).
Содержание COMBIACX
Страница 27: ...AFCZP0BC COMBIACX ACEX User Manual Page 27 81 8 DRAWINGS 8 1 Mechanical drawing COMBIACX...
Страница 28: ...Page 28 81 AFCZP0BC COMBIACX ACEX User Manual 8 2 Mechanical drawing ACEX...
Страница 29: ...AFCZP0BC COMBIACX ACEX User Manual Page 29 81 8 3 Connection drawing COMBIACX...
Страница 30: ...Page 30 81 AFCZP0BC COMBIACX ACEX User Manual 8 4 Connection drawing ACEX...
Страница 35: ...AFCZP0BC COMBIACX ACEX User Manual Page 35 81 10 3Description of the console menu 10 3 1 COMBIACX ACEX Menu...