H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany • Tel +49 241 9105010
Fax +49 241 91050138 • [email protected] • www.zander-aachen.de
10
Operating Manual MVisio Industrial HMI Lite
4.4
Durability information
Parameter
Data
LED background lighting
More than 40 000 hours. (The time after which the bright-
ness of the background lighting has decreased by 50% at
a temperature of 25°C).
Immunity to burst
± 2 kV DC power connection
± 1kV signal line
EN 61000-4-4
Immunity to surge
± 0,5 kV DC mains connection (line to ground)
± 0,5 kV DC mains connection (conductor to
conductor)
± 1 kV signal line (line to ground)
EN 61000-4-5
Immunity to powered
H.F.
0.15 / 80 MHz, 10 V
EN 61000-4-6
Immunity to mains fre-
quency magnetic field
Casing, 50/60 Hz, 30 A/m
EN 61000-4-8
Immunity to
short voltage drops
and fluctuations
Connection: AC mains;
Level:
100 % duration: 1 cycle and 250 cycles (50 Hz);
40 % duration: 10 cycles (50 Hz);
70 % duration: 25 cycles (50 Hz);
Test performed on the 230 VAC side of the power supply. DC 0%, Dura-
tion: 10 ms. 20 fields x 1 s
EN 61000-4-
11
Test performed on the 24 VDC side of the testee.
EN 61000-4-
29
Note!
If the ambient temperature is 40° C or higher, the quality/reliability/durability