background image

MOUNTING

OPERATION MODES 

•  The ROP-21 receiver is designed to be mounted in a junction box. Its dimensions enable both 

flush (Ø60 minimum) and surface mounting. In case of a flush junction box, a deepened box is 

recommended as it makes mounting easy with a large number of wiring and a big cross-section 

of connection wires.

•  The device is designed for a single-phase installation and must be installed in accordance with 

standards valid in a particular country. The device should be connected according to the details 

included in this manual instruction. Installation, connection and control should be carried out 

by a qualified electrician staff, who act in accordance with the service manual and the device 

functions. For safety reasons, do not mount the device without casing or with a damaged one, 

as an electric shock may occur.

CAUTION! Before installation make sure the connection cables are not under voltage.
INSTALLATION:

1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector com-

bined to the proper circuit.

2. Check if there is no voltage on the connection cables by means of a special measuring equip-

ment.

3. Connect the device cables with the terminals in accordance with the installing diagram.

4. Install ROP-21 in a junction box.

5. Switch on the power supply from the mains.

MOUNTING REMARKS:

1. Do not mount receivers in a close proximity to each other (if there is a possibility, keep a distance 

of minimum 15 cm between receivers). Particularly, avoid installation of one receiver over the 

another.

2. The maximum output load must be obeyed:

•  incandescent and halogen lamps: 750 W / channel

•  fluorescent CFL lamps: 250 W / channel

•  dimmable LEDs: 60 W / channel.

3. During mounting, make sure the receiver is not exposed to direct water and operation in an in-

creased humidity environment. The mounting ambient temperature range should be within the 

range from -10 to + 55 °C.

4. The ROP-21 receiver is designed to be mounted indoor. In case the receiver is mounted outdoor, 

it must be placed in an additional hermetic casing

5. Wired control switches can be connected to the IN1 and IN2 inputs of ROP-21 receiver. By de-

fault, the inputs are adapted to cooperate with monostable push-buttons in a bistable mode. It 

means that each subsequent impulse given to the IN1 or IN2 input causes the output mode is 

changed to an opposite mode.

6. After a receiver has been installed, it is important to check if it operates correctly. In case of 

control by means of the EXTA LIFE system transmitters, they must be first programmed with a 

receiver (see Programming transmitters). In case of cooperation with a controller, a correct pair-

ing of a receiver with a controller is required (see Register of receivers in the EXTA LIFE system).

7. After power supply has been applied, the receiver will carry out service activities for 

about 5 seconds (it is signalled by a green STATUS LED, it will flash at an interval of 1 

second). During this time the control of a receiver is not possible.

CAUTION: Input functionality (switch type, operation mode) can be changed by means of the 

EXTA LIFE mobile application. It is necessary to install a controller in the system and pair it 

with ROP-21 receiver – see Input functionality.

Switch on / switch off mode 

•  In the switch on / switch off mode two push-buttons of a transmitter are used. One push-button 

always realises the “switch on” function and the second one the “switch off” function. 

CAUTION! This mode is used to control a larger number of receivers by means of one 

transmitter. 

Bistable mode

•  In the bistable mode only one push-button of a transmitter is used to control a receiver. The 

same push-button realises the “switch on” and “switch off” function. Output control is realised 

as a cyclical change of one mode by subsequent pressing the transmitter’s button. The bistable 

mode allows for an independent control of a larger number of receivers by means of one trans-

mitter. For example, by means of 4 push-button remote control P-457/4, an independent control 

of 4 circuits is possible.

CAUTION!  It is not recommended that one push-button in a bistable mode is assigned to 

more than one receiver. It can have output mode jitter effect during control.

Monostable mode

•  In the monostable mode, only one push-button of a transmitter is used to control a receiver.

•  A receiver’s output is switched on as long as the transmitter’s push-button is pressed.

Time mode

•  In time mode only one push-button of a transmitter is used to control a receiver.

•  A receiver’s output is switched on after a transmitter’s push-button is pressed, and it switches 

off automatically after the adjusted time is over. Pressing a transmitter’s push-button during time 

measurement causes the receiver’s output is switched off earlier (system without time retrigger). 

Time switch on is programmed in the range from 1 sec. to 18 hrs. In case of ROP-21 receiver, it is 

possible to adjust an independent time for each push-button programmed in time mode, for local 

inputs and for control by means of an application. 

Switch on mode 

•  This mode is available only by means of switches connected to IN1/IN2 inputs. In this mode, it 

is only possible to switch on a receiver’s output.

Switch off mode

 

•  This mode is available only by means of switches connected to IN1/IN2 inputs. In this mode, it 

is only possible to switch off a receiver’s output.

Operation

mode

EXTA LIFE 

transmitters

EXTA LIFE 

application

Monostable 

switch

Bistable

switch

Switch on/switch off mode

+

+ (default)

-

-

Bistable mode

+

-

+ (default)

+

Monostable mode

+

-

+

-

Time mode

+

+

+

+

Switch on mode

-

-

+

+

Switch off mode

-

-

+

+

In case of EXTA LIFE radio transmitters, the operation mode is carried out by adding transmitter’s 

push-buttons to a receiver. In other cases, the operation mode is configured by means of the 

EXTA LIFE application.

Содержание ROP-21

Страница 1: ...n switching off time Number of external inputs 2 Cooperation with push buttons monostable push buttons bistable Operating modes for external inputs only switching on only switching off bistable monost...

Страница 2: ...lity The receiver has an implemented function of a re mote software update by means of the controller FUNCTIONALITY 1 The ROP 21 receiver can be simultaneously controlled by EXTA LIFE system transmitt...

Страница 3: ...ied the receiver will carry out service activities for about 5 seconds it is signalled by a green STATUS LED it will flash at an interval of 1 second During this time the control of a receiver is not...

Страница 4: ...ATUS LED flashes orange to signal the push buttons have been assigned correctly Bistable mode 1 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 2 In 5 sec press the b...

Страница 5: ...mitter should cooperate with a receiver In case of ROP 21 the switch on switch off bistable monostable and time modes are possible 6 Choose push buttons of a transmitter that will be assigned remotely...

Страница 6: ...y transmitter s push buttons from a receiver it is required that the receiver is paired with the EXTA LIFE controller To do the above the following steps must be carried out 1 Choose the Configure opt...

Страница 7: ...con is assigned to the ROP 21 receiver 7 The receivers just after pairing can be controlled at once by means of application buttons The receiver s mode is signalled by a switch position and a switch i...

Страница 8: ...guration change 1 Activate the application and enter the Device screen 2 Select the Configure option from the receiver s menu 3 Expand the screen and configure separately the IN1 and IN 2 input First...

Страница 9: ...ed only by an authorised user an administra tor It is required to connect the EXTA LIFE controller to the Internet to carry out the update The current ROP 21 software update is displayed in the Config...