DESCRIPTION
FEATURES
• nominal supply voltage 230 V AC,
• compatible with a controller and EXTA LIFE system transmitters,
• 1 output channel (NO dry contact),
• two-way transmission – current output mode indicated in the application,
• programmable output mode after power supply is switched on,
• 2 programmable external inputs,
• connection possibility of monostable or bistable switches,
• 4 operation modes in cooperation with transmitters (switch on / switch off, bistable, monostable,
time),
• 2 operation modes in cooperation with a controller (switch on / switch off, time)
• independent time for radio transmitters, controllers and external input,
• independent remote software update,
• dedicated to control any devices of <750 W power,
• mounting in Ø60 mm junction box.
Radio flush receiver ROP-21 is a final element of the EXTA LIFE system, which allows to control
home and office devices. The output in the form of a single normally open contact gives a pos-
sibility to control low voltage (e.g. 12/24 V AC/DC) and high voltage (230 V AC) circuits. ROP-21
is reliable also during a remote triggering of other devices – it can be used during transmission of
control signals. The receiver can additionally be used to control electro valves in heating systems.
Current mode of the device controlled by ROP-21 is shown in the mobile application, due to a two-
way communication between a receiver and a controller. This method of communication allows for
parameterisation of a receiver and a remote adding of transmitters (without a physical access to a
receiver). Frame encoding algorithm ensures control security. ROP-21, apart from the controller,
can be simultaneously operated by the EXTA LIFE system transmitters. A larger number of transmit-
ters can be added to a receiver which, in turns, enables an independent control from several places.
The device is designed for (surface and flush) junction box installation. The additional configured
wired inputs increase the control functionality. The receiver has an implemented function of a re-
mote software update by means of the controller.
FUNCTIONALITY
1. The ROP-21 receiver can be simultaneously controlled by:
• EXTA LIFE system transmitters (switch on / switch off, bistable, monostable, time)
• EXTA LIFE mobile application, after pairing with a controller (switch on / switch off and time
modes)
• IN1, IN2 external inputs (operating mode depends on a switch type – see Functionality of
inputs).
2. Current receiver’s mode is shown in the mobile application.
3. It is possible to assign a larger number of push-buttons of EXTA LIFE transmitters to one re-
ceiver – maximum 96 pairs (e.g. 24 transmitters in the switch on/switch off mode).
4. Transmitters’ push-buttons can be assigned to a receiver “locally” by means of the PROG. push-
button or „remotely” by means of the mobile application.
5. Few transmitters can cooperate with one transmitter – it is recommended that a transmitter is
assigned to each receiver in the switch on / switch off mode.
6. A dimmer can be paired only with one EXTA LIFE controller. After pairing the receiver is not
visible for other controllers.
7. Push-buttons added to a receiver’s memory can be selectively deleted.
8. There is a possibility to delete simultaneously all push-buttons added to a receiver’s memory
(reset to default settings).
9. Basic ROP-21 parameters are configured by means of a mobile application.
10. A remote software update of a receiver is also possible due to a mobile application (the EXTA
LIFE controller must be connected to the Internet).
DEFAULT SETTINGS
Parameter
Default settings
Configuration
possibilities
output mode after power supply
has been applied
• Switched off (open contacts 11-14) • yes – mobile application
Input types: IN1, IN2
• cooperation with monostable
(push-buttons) switches
• yes – mobile application
IN1, IN2 input operation mode • bistable
• yes – mobile application
default time for output*
• 10 s
• yes – mobile application
• PROG push-button
*refers to push-buttons assigned to a receiver in time mode
CONNECTION
APPEARANCE
Input terminals
Output terminals
Power supply terminals
Signalling diode - RGB
(receiving / transmission / mode)
Programming push-button