1. To install an insert, first line up the 3 insert chamfers
with the 3 screw pockets in the ASR-E top plate.
2. Screw the 3 M4 x 8 flat head screws into the holes in
the top plate as shown. Tighten the screws evenly until
the insert is held securely.
3. If required, the insert can be leveled using the 3 M4
set screws adjacent to the flat head screws. Before
adjusting the set screws, loosen the flat head screws.
Setting Home and Away Sensors
The ASR-E provides adjustable travel limits for each axis. A home sensor sets the 0 position of each axis and an
away sensor determines the maximum travel range. As long as the "limit_auto-detect" setting is enabled, each
stage will not be able to move past these limits.
Limit adjustment is performed by moving the magnets which trigger the sensor. The limit switch magnets are
attached to the bottoms of the limit adjustment screws shown in the pictures below.
Important:
If adjusting the magnets outwards, make adjustments in small increments. Exceeding the
nominal factory set travel range by more than 3 mm can cause the device to become stuck at one end of travel.
ASR100B120B-E