noisy environments. The typical value for the pull-up resistor (R
LOAD
) is 10 kΩ and for the bypass capacitor is 0.1 uF
to 1 uF. The larger the capacitance, the better the noise filtering but the slower the response time.
Installation
Shipping Plate Removal
The ASR205B205B-E and ASR305B305B-E stages are fitted with sheet metal plates to prevent shock loads from
the stage during shipping. Follow the instructions below to remove the shipping plates.
Instructions
ASR305B305B-E
1. Connect the stage to a controller.
2. Remove the 8 M3 screws securing the shipping plates to the
base and mid-plates as shown.
3. With these screws removed, use the controller to move the
upper-axis in order to gain access to the screws on the
underside of the top-plate as shown.
4. Remove the two screws holding the upper-axis shipping
plate to the underside of the top plate. Move the upper-axis in
the opposite direction in order to access and remove the two
screws under the opposite side of the top-plate. Slide the
upper-axis shipping plate out and set it aside.