For more details about these inserts, please see our
accessory page
.
Installation and Removal - ASR050B050B-E and ASR100B120B-E
On the ASR050B050B-E and ASR100B120B-E, the inserts are held in place by a spring clip in one corner of the
ASR-E aperture. To install an insert, place the one corner up against the spring first. While holding this corner
down, push the insert towards the spring clip and snap the opposing corner into place. Removal is the reverse of
this procedure.
For most applications, the spring clip should provide sufficient force to hold the insert in place, while still allowing
quick changes between inserts. For applications requiring more secure mounting, custom inserts can be provided
that can be secured to the ASR-E using 4 M2 screws.
Instructions
ASR100B120B-E
1. To install an insert, first position the corner next to
the spring clip as shown.
2. While holding down the corner next to the spring
clip, push the opposite corner down.
Installation and Removal - ASR205B205B-E and ASR305B305B-E
On the ASR205B205B-E and ASR305B305B-E, the inserts are held in place by 3 M4 flat head screws. The screws
mate with 3 matching chamfers on the insert to kinematically constrain it. Some inserts also allow for mounting
using 16 or 24 M3 screws around the perimeter of the insert. The perimeter screws will secure the insert against
high loads, but may compromise the flatness of the stage. It is only recommended that these screws be used when
the necessary to prevent the insert from shifting under high loads.
Instructions
ASR305B305B-E