User’s Manual
49
Enables the RS485 transmitter. Transmitted data get echo’ed back into the receive data buffer. These
echo’ed data could be used to know when to disable the transmitter by using one of the following
methods:
Byte mode—disable the transmitter after the same byte that is transmitted is detected in the receive
data buffer.
Block data mode—disable the transmitter after the same number of bytes transmitted is detected in the
receive data buffer.
serMode()
must be executed before running this function.
SEE ALSO
serMode, ser485Rx
Disables the RS-485 transmitter. This puts the OP7200 in listen mode, which allows it to receive data
from the RS-485 interface.
serMode()
must be executed before running this function.
SEE ALSO
serMode, ser485Tx
void ser485Tx(void);
void ser485Rx(void);
Содержание eDisplay OP7200
Страница 1: ...eDisplay OP7200 VGA Operator Control Panel User s Manual 019 0116 021001 A ...
Страница 6: ...eDisplay OP7200 ...
Страница 44: ...38 eDisplay OP7200 ...
Страница 117: ...User s Manual 111 APPENDIX A SPECIFICATIONS Appendix A provides the specifications for the OP7200 ...
Страница 128: ...122 eDisplay OP7200 ...
Страница 136: ...130 eDisplay OP7200 ...
Страница 144: ...138 eDisplay OP7200 ...
Страница 146: ...140 eDisplay OP7200 ...
Страница 150: ...144 eDisplay OP7200 ...
Страница 152: ......