58
eDisplay (OP7200)
Writes the calibration constants, gain, and offset for an input based on its designated channel code posi-
tion from global table
_adcCalib
. The constants are stored in the the top 1K of the reserved user
block memory area. Use the sample program
USERBLOCKINFOR.C
in
SAMPLES\OP7200
to get
the addresses reserved for the calibration data constants and the addresses available for use by your
application program.
NOTE: This function cannot be run in RAM.
PARAMETERS
channel
is the analog input channel number corresponding to AIN0–AIN7:
opmode
is the mode of operation:
SINGLE
—single-ended input line
DIFF
—differential input line
int anaInEEWr(unsigned int channel, int opmode,
unsigned int gaincode);
0x00
AIN0
0x01
AIN1
0x02
AIN2
0x03
AIN3
0x04
AIN4
0x05
AIN5
0x06
AIN6
0x07
AIN7
0xFF
All Channels
channel
SINGLE
DIFF
0
+AIN0
+AIN0 -AIN1
1
+AIN1
—
2
+AIN2
+AIN2 -AIN3
3
+AIN3
—
4
+AIN4
+AIN4 -AIN5
5
+AIN5
—
6
+AIN6
+AIN6 -AIN7
7
+AIN7
—
Содержание eDisplay OP7200
Страница 1: ...eDisplay OP7200 VGA Operator Control Panel User s Manual 019 0116 021001 A ...
Страница 6: ...eDisplay OP7200 ...
Страница 44: ...38 eDisplay OP7200 ...
Страница 117: ...User s Manual 111 APPENDIX A SPECIFICATIONS Appendix A provides the specifications for the OP7200 ...
Страница 128: ...122 eDisplay OP7200 ...
Страница 136: ...130 eDisplay OP7200 ...
Страница 144: ...138 eDisplay OP7200 ...
Страница 146: ...140 eDisplay OP7200 ...
Страница 150: ...144 eDisplay OP7200 ...
Страница 152: ......