User’s Manual
103
5.2 TCP/IP Sample Programs
We have provided a number of sample programs demonstrating various uses of TCP/IP for
networking embedded systems. These programs require that you connect your PC and the
OP7200 together on the same network. This network can be a local private network (pre-
ferred for initial experimentation and debugging), or a connection via the Internet.
5.2.1 How to Set IP Addresses in the Sample Programs
Most of the sample programs such as shown in the example below use macros to define the
IP address assigned to the board and the IP address of the gateway, if there is a gateway.
#define MY_IP_ADDRESS "10.10.6.170"
#define MY_NETMASK "255.255.255.0"
#define MY_GATEWAY "10.10.6.1"
#define MY_NAMESERVER "10.10.6.1"
In order to do a direct connection, the following IP addresses can be used for the OP7200:
#define MY_IP_ADDRESS "10.1.1.2"
#define MY_NETMASK "255.255.255.0"
// #define MY_GATEWAY "10.10.6.1"
// #define MY_NAMESERVER "10.10.6.1"
In this case, the gateway and nameserver are not used, and are commented out. The IP
address of the board is defined to be
10.1.1.2
. The IP address of you PC can be defined
as
10.1.1.1
.
IP Addresses After Dynamic C 7.30
With the introduction of Dynamic C 7.30 we have taken steps to make it easier to run
many of our sample programs. Instead of the
MY_IP_ADDRESS
and other macros, you will
see a
TCPCONFIG
macro. This macro tells Dynamic C to select your configuration from a
list of default configurations. You will have three choices when you encounter a sample
program with the
TCPCONFIG
macro.
1. You can replace the
TCPCONFIG
macro with individual
MY_IP_ADDRESS
,
MY_NETMASK
,
MY_GATEWAY
, and
MY_NAMESERVER
macros in each program.
2. You can leave
TCPCONFIG
at the usual default of 1, which will set the IP configurations
to
10.10.6.100
, the netmask to
255.255.255.0
, and the nameserver and gateway
to
10.10.6.1
. If you would like to change the default values, for example, to use an IP
address of
10.1.1.2
for the RCM3200 board, and
10.1.1.1
for your PC, you can
edit the values in the section that directly follows the “General Configuration” com-
ment in the
TCP_CONFIG.LIB
library. You will find this library in the
LIB\TCPIP
directory.
3. You can create a
CUSTOM_CONFIG.LIB
library and use a
TCPCONFIG
value greater
than 100. Instructions for doing this are at the beginning of the
TCP_CONFIG.LIB
file.
There are some other “standard” configurations for
TCPCONFIG
that let you select differ-
ent features such as DHCP. Their values are documented at the top of the
TCP_CONFIG.LIB
library. More information is available in the Dynamic C TCP/IP
User’s Manual.
Содержание eDisplay OP7200
Страница 1: ...eDisplay OP7200 VGA Operator Control Panel User s Manual 019 0116 021001 A ...
Страница 6: ...eDisplay OP7200 ...
Страница 44: ...38 eDisplay OP7200 ...
Страница 117: ...User s Manual 111 APPENDIX A SPECIFICATIONS Appendix A provides the specifications for the OP7200 ...
Страница 128: ...122 eDisplay OP7200 ...
Страница 136: ...130 eDisplay OP7200 ...
Страница 144: ...138 eDisplay OP7200 ...
Страница 146: ...140 eDisplay OP7200 ...
Страница 150: ...144 eDisplay OP7200 ...
Страница 152: ......