User’s Manual
53
Reads the state of an analog input channel and uses the previously set calibration constants to convert it
to volts.
PARAMETERS
channel
is the analog input channel number (0 to 7) corresponding to AIN0–AIN7
opmode
is the mode of operation:
SINGLE
—single-ended input line
DIFF
—differential input line
gaincode
is the gain code of 0 to 7:
RETURN VALUE
A voltage value corresponding to the voltage on the analog input channel.
SEE ALSO
anaInCalib, anaIn, brdInit
float anaInVolts(int channel, int opmode,
int gaincode);
channel
SINGLE
DIFF
0
+AIN0
+AIN0 -AIN1
1
+AIN1
—
2
+AIN2
+AIN2 -AIN3
3
+AIN3
—
4
+AIN4
+AIN4 -AIN5
5
+AIN5
—
6
+AIN6
+AIN6 -AIN7
7
+AIN7
—
Gain Code
Multiplier
Voltage
Range
0
×1
0–20 V
1
×2
0–10 V
2
×4
0–5 V
3
×5
0–4 V
4
×8
0–2.5 V
5
×10
0–2 V
6
×16
0–1.25 V
7
×20
0–1 V
Содержание eDisplay OP7200
Страница 1: ...eDisplay OP7200 VGA Operator Control Panel User s Manual 019 0116 021001 A ...
Страница 6: ...eDisplay OP7200 ...
Страница 44: ...38 eDisplay OP7200 ...
Страница 117: ...User s Manual 111 APPENDIX A SPECIFICATIONS Appendix A provides the specifications for the OP7200 ...
Страница 128: ...122 eDisplay OP7200 ...
Страница 136: ...130 eDisplay OP7200 ...
Страница 144: ...138 eDisplay OP7200 ...
Страница 146: ...140 eDisplay OP7200 ...
Страница 150: ...144 eDisplay OP7200 ...
Страница 152: ......