50
eDisplay (OP7200)
4.4.5 A/D Converter Inputs (OP7200 only)
Reads the state of an analog input channel.
PARAMETERS
channel
is the analog input channel number (0 to 7) corresponding to AIN0–AIN7
opmode
is the mode of operation:
SINGLE
—single-ended input line
DIFF
—differential input line
gaincode
is the gain code of 0 to 7:
RETURN VALUE
A value corresponding to the voltage on the analog input channel, which will be:
0–2047 for 11-bit A/D conversions (signed 12th bit)
SEE ALSO
anaInVolts, anaInCalib, brdInit
int anaIn(int channel, int opmode, int gaincode);
channel
SINGLE
DIFF
0
+AIN0
+AIN0 -AIN1
1
+AIN1
—
2
+AIN2
+AIN2 -AIN3
3
+AIN3
—
4
+AIN4
+AIN4 -AIN5
5
+AIN5
—
6
+AIN6
+AIN6 -AIN7
7
+AIN7
—
Gain Code
Multiplier
Voltage
Range
0
×1
0–20 V
1
×2
0–10 V
2
×4
0–5 V
3
×5
0–4 V
4
×8
0–2.5 V
5
×10
0–2 V
6
×16
0–1.25 V
7
×20
0–1 V