4.5 FILL BED
1. Press the ‘Fill Bed’ button on the control
panel. This will prompt the powder feeder
and gantry to deposit and spread powder
over the build pallet. It will continue
spreading until the build pallet is covered.
2. To cancel the operation, press ‘Online’ on
the control panel.
4.6 REMOVE
POWDER
FROM
OVERFLOW CHUTE
1. Place one end of the vacuum hose into
the overflow chute vacuum receptacle.
2. Place the other end of the vacuum hose
into the powder feeder vacuum receptacle.
3. From the software select the ‘Empty
Overflow’ option under the 810Service
menu. The vacuum and vibrator located
on the overflow chute will operate
automatically.
4. The vacuum and vibrator will stop when
the overflow chute is empty.
To reduce airborne powder particles, turn
on the vacuum and remove the vacuum
hose from both the overflow chute vacuum
receptacle and feeder vacuum receptacle.
Then turn off the vacuum.
Vacuum Hose
Feeder Vacuum
Receptacle
Overflow Chute
Vacuum Receptacle
PLEASE NOTE:
The powder should
spread evenly throughout the build
pallet. If it does not spread evenly,
manually spread powder over the build
pallet by pressing ‘Spread’ on the
control panel.
PLEASE NOTE
: The airflow from the
powder feeder may stall for a minute
while cleaning the filter. The vacuum
and the vibrator in the printer will
remain on. After cleaning, the powder
feeder will resume emptying the
overflow chute.