12.8 BLEEDING AIR FROM THE FLUID SYSTEM
Air may get into the fluid system through leaks or have run low on binder. If you need to remove
air from your system, follow the procedure below:
1. Fill the binder jug with binder solution.
2. Select the ‘Flush Binder’ option under the
Service menu.
3. Flush binder for 5 minutes.
4. Unpark carriage and remove print heads.
5. Select the ‘Bleed Air’ option under the
810Service menu.
6. Assemble the syringe (part number
10674) and needle (part number 13115) if
needed from your toolkit by screwing on
the needle at the end of the syringe.
Septum
7. Remove plunger from syringe.
8. Insert needle into septum and wait until
you do not see any air entering into the
syringe, characterized by bubbles in the
fluid.
9. Continue for every septum.
10. Close the carriage cover, repark the
carriage using the ZPrint Software, and
change print heads as described in
Section 10,
Changing and Aligning the
Print Heads
.