SECTION 7: SYSTEM MAINTENANCE
YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, PA • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
Page 76
NJEX ZEO Version 04/13/2021
Safety Notes
– Maintenance
general safety notes in Section 1
of this manual should be reviewed prior to performing any
maintenance on NJEX ZEO units.
• All installation, maintenance, troubleshooting, etc. should be performed by a trained
professional.
• While servicing units, proper PPE must be worn such as gloves and protective eyewear.
• Purging and venting the NJEX ZEO system purges gas and vents pressure in the suction lines
of the system. This allows for maintenance on the inlet filters, transfer pump, and suction check
valves. If maintenance is required on a discharge check valve or the discharge lines, the
discharge pressure must be relieved.
WARNING: Power must be disconnected or locked out from the NJEX ZEO system before
performing any troubleshooting or repair to electrical components.
CAUTION: Vent Valve must be closed in all operations excluding venting. Failure to close
V5 during other operations will result in spilled odorant.