During operation, the N-400 controller will record the injection rate and log this data and any
active alarms to the MM-400 Memory Module. The MM-400 Memory Module can be removed
from the N-400 controller so the data can be retrieved using
YZ System’s Sentry Utility Software
for future reference.
CAUTION: Excessive tubing lengths should be avoided. Installation of the NJEX ZEO
Odorization system should be as close to the point of injection and Odorant Storage Tank
as possible. Tubing length from the Odorant Storage Tank to the system should not exceed
15 feet (4.5 meters). Discharge tubing length should not exceed 50 feet (15 meters). The
tubing size should be maintained as indicated in this manual. If longer tubing lengths are
required, consult YZ Systems Technical Services at; 800.653.9435 or 1.281.362.6500.