Install-Xander_Insert_BUILT-IN_ZC - 2021-11-25.docx www.yunca.co.nz
Page 11 of 18
P.
Xander Insert Seismic Fixings
P1.
Follow
local Council’s specifications.
P2.
Prior to installation, ensure the cavity floor is level both ways, smooth and bump
free. Also ensure the mantel face is perpendicular in relationship to the cavity floor.
P3.
Ensure the unit is securely fixed using sleeve anchors or similar at the locations
shown in the images on this page.
(Fig. 9)
Q.
Xander Fan - Electrical Supply
Q1.
Remove the front fascia from its separate box and packaging and set it aside in a
safe position. You can use the box and polystyrene packing as a work surface to
raise it up if you wish.
Q2.
3-Pin Plug
If the fan is to be plugged into an electrical outlet in the room, take the RS321-174
mains power cable (plastic bag in box) and plug it into the IEC C14 socket on the
underside of the circuit box on the rear of the fascia. Pass the cable through the slot
in the fascia, crimp the cable grip bush (in the plastic bag with the power cable) over
the cable outside the fascia and pull the bush and cable back into the hole in the
fascia.
Q3.
Hardwired
Should you wish to “hardwire” the fan unit, as a Registered
Electrician you can use TPS cable. Remove the screw fixed
panel on the rear of the circuit box, remove the internal wiring
and IEC C14 socket and substitute your TPS in place of the
socket. You must be a Registered, Certified Electrical
tradesperson to do this. Plug the slotted hole in the side of
the fascia with the 16mm black, rubber grommet supplied in
the plastic bag
Fig. 9