We recommend that your dealer representative or YSI regional representative assist with initial
setup and orientation. YSI warranty and product performance claims, however, are not
dependent upon installation by factory or dealer personnel.
Remove the instrument from the shipping container. Be careful not to discard any parts or
supplies. Check off all items on the packing list and inspect all assemblies and components for
damage. In the event of damaged or missing parts, contact YSI Customer Service or your
Dealer Representative immediately.
Note that reagents for the 2700 SELECT Analyzer are not packaged in the same carton as the
instrument. These materials must be ordered separately as starter supplies and will arrive in a
separate package.
DO NOT PLUG THE INSTRUMENT IN AT THIS TIME. You should apply power only
when directed to do so in the setup instructions.
If you ordered the 2700 SELECT with the 2710 Turntable, first set up the 2700 SELECT. Once
the 2700 SELECT is operating properly, refer to the YSI 2710 Turntable Operations Manual.
Notes On Safety (Electrical precautions)
1.
BEFORE connecting the power cord, check the line voltage selector and confirm that the
selected voltage matches the local power supply (Section 2.5).
2.
Use ONLY the line power cord supplied with the instrument. Connect the plug to a
matching three-pronged wall receptacle.
3.
Use ONLY fuses of the type supplied (Section 7.9). Replacement power cords and fuses
can be obtained from YSI, or your Dealer Representative (Appendix F, G).
4.
Do NOT use an extension cord without protective grounding.
5.
Do NOT remove rear cover. There are no user serviceable parts inside.
6.
Repairs are to be performed only by trained and approved personnel.
7.
This instrument must be connected to a protectively grounded (earthed) outlet.
8.
The following notices are provided in compliance with IEC1010 Part 1 1990.
8.1 Fuses F1-F7 on the main circuit board are type: Subminiature (F) to UL 198G Standard.
Rating: F1-F5, 1A; F6-F7, 2A. These fuses are NOT operator replaceable.
8.2 See Appendix G for mains plug wiring and fusing instructions.
9.
If the equipment is used in a manner not specified by YSI, the protection provided by the
equipment may be impaired.
WARNING: For auxiliary connection, refer to the YSI 2710 Turntable Operation Manual or the
YSI 2730 Monitor and Control Accessory User’s Manual. Use with the YSI 2710
Turntable or YSI 2730 Monitor/Control Accessory only.
WARNING: For remote connection, refer to section 9. Communications. Equipment should be
EN 61010 or EN 60950 approved only.
10. The mains (power) switch is for functional purposes ONLY. To disconnect the instrument
from the mains supply, unplug the mains power cord from the back of the instrument.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание 2700D
Страница 50: ...3 10 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 96: ...5 26 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 104: ...6 8 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 118: ...7 14 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 144: ...9 18 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 154: ...D 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 156: ...E 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 160: ...F 4 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 162: ...G 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 164: ...H 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...