JOHNSON CONTROLS
SAFETY DATA
YORK “L” OIL
Classification
Non-hazardous
In contact with skin
Minimally irritating. No first aid necessary. Exercise reasonable personal cleanliness including
cleansing exposed skin areas several times daily with soap and water. Launder soiled work
clothes at least weekly.
In contact with eyes
Flush eyes with eyewash solution or clean water for 15 minutes and consult a physician.
Ingested
May cause nausea and diarrhea. Obtain immediate medical attention.
Inhalation
If oil mist is inhaled, remove to fresh air and consult a physician.
Occupational
Not determined.
exposure limits
Stability
Stable but hygroscopic - store in sealed containers.
Conditions to avoid
Strong oxidizers, caustic or acid solutions, excessive heat. May degrade some paints and
rubber materials.
Hazardous
Not fully, Analogous compounds evolve carbon monoxide, carbon dioxide and other
decomposition
unidentified fragments when burned. Burning may evolve irritating/noxious fumes.
Respiratory protection
Use in well ventilated areas - ventilate locally.
Protective clothing
Goggles or face shield should be worn. Gloves not necessary, but recommended, especially
for prolonged exposure.
Spill / Leak procedure
Wear suitable protective equipment. Especially goggles. Stop source of spill. Use absorbent
materials to soak up fluid (i.e. sand, sawdust and commercially available materials).
Disposal
Incinerate the oil and all associated wastes in an approved facility in accordance with local
laws and regulations governing oily wastes.
Fire extinguishing
Flash point over 300°C. Use dry chemical, carbon dioxide or foam. Spraying water on hot or
data
burning liquid may cause frothing or splashing.
If a leak or spill has not ignited use water spray to disperse the vapors and to provided protec
-
tion for persons attempting to stop the leak.
Containers
Fire exposed containers should be kept cool with water sprays.
Fire fighting
Self contained breathing apparatus should be worn in fire conditions.
protective equipment
REFRIGERANT OIL DATA:
MATERIAL SAFETY DATA
1
Содержание YCAS0098EB
Страница 36: ...36 JOHNSON CONTROLS POWER AND CONTROL PANEL LAYOUTS WYE DELTA TYPICAL FIG 8 POWER PANEL SECTION 00263VIP 4...
Страница 50: ...50 JOHNSON CONTROLS This page intentionally left blank...
Страница 61: ...61 JOHNSON CONTROLS FORM 201 18 NM7 This page intentionally left blank 7...
Страница 64: ...64 JOHNSON CONTROLS Technical Data ELEMENTARY DIAGRAM FIG 18 ELEMENTARY DIAGRAM ACROSS THE LINE START...
Страница 68: ...68 JOHNSON CONTROLS Technical Data ELEMENTARY DIAGRAM FIG 21 ELEMENTARY DIAGRAM WYE DELTA START...
Страница 70: ...70 JOHNSON CONTROLS Technical Data FIG 22A CONTROL PANEL COMPONENT LOCATIONS...
Страница 71: ...71 JOHNSON CONTROLS FORM 201 18 NM7 LD03280 FIG 22B POWER PANEL COMPONENT LOCATION 7...
Страница 72: ...72 JOHNSON CONTROLS Technical Data LEGEND LD03281...
Страница 73: ...73 JOHNSON CONTROLS FORM 201 18 NM7 LD03282 LD03283 LD03284 7...
Страница 74: ...74 JOHNSON CONTROLS Technical Data CONNECTION DIAGRAM SYSTEM WIRING LD06256 LD03231 LD03232...
Страница 75: ...75 JOHNSON CONTROLS FORM 201 18 NM7 COMPRESSOR TERMINAL BOX LD03233 7...
Страница 76: ...76 JOHNSON CONTROLS LD03285 Technical Data...
Страница 77: ...77 JOHNSON CONTROLS FORM 201 18 NM7 3 4 5 6 3 4 5 6 7 8 5 6 3 4 7 8 9 10 LD06840A 7...
Страница 113: ...113 JOHNSON CONTROLS FORM 201 18 NM7 COMPRESSOR COMPONENTS CONT D FIG 40 COMPRESSOR COMPONENTS LD03669 7...
Страница 114: ...114 JOHNSON CONTROLS COMPRESSOR COMPONENTS CONT D FIG 41 COMPRESSOR COMPONENTS LD03670 Technical Data...
Страница 181: ...181 JOHNSON CONTROLS FORM 201 18 NM7 NOTES...
Страница 182: ...182 JOHNSON CONTROLS This page intentionally left blank...
Страница 183: ...183 JOHNSON CONTROLS FORM 201 18 NM7 This page intentionally left blank...