6.1 Preparation for Starting
Operation
NOTE
It is required to set security and network
information to enable the transmitter to be
connected to the Field Wireless Network. For
more details, refer to subsection 6.4 “Connecting
to the Field Wireless Network”.
1) Checking Installation and Wiring
Ensure that the transmitter is installed correctly
and the temperature sensor is connected
correctly according to the procedures described
in section 4 “Installation”, and section 5 “Wiring”.
When connecting the thermocouple, particular
attention needs to be paid because the
transmitter cannot detect a wrong polarity
connection.
2) Insert batteries into the battery case, and install
to the transmitter. To insert batteries into the
battery case, be careful to polarity of batteries
and battery case. For details of Installation of
battery, refer to section 8.4.5 and 8.4.6.
Battery case is installed in the transmitter when
shipped from the factory, however, batteries are
sold separately and not included.
3) Using the device configuration tool confirm
that transmitter is operation properly. Check
parameter values or change the setpoints as
necessary.
If the transmitter is equipped with an integral
indicator, its indication can be used to confirm
that the transmitter is operating properly.
For details on how to confirm this, refer to
subsection 7.4 “Self-Diagnostics.”
ISA100 devices display self-diagnostic
information in an easy-to-understand manner
using four categories (Check function,
Maintenance required, Failure, and Off
specification) according to NAMUR NE107*
* NAMUR NE107 “Self-Monitoring and Diagnosis of Field
Devices”
■ Confirm that transmitter is operating
properly by integral indicator.
If the transmitter is faulty, an error code is displayed.
F0601.ai
Self-diagnostic error on the integral indicator
(Faulty transmitter)
Figure 6.1 Integral Indicator with Error Code
NOTE
If any of the above errors are indicated on the
display of the integral indicator or the device
configuration tool, refer to subsection 8.5.3 for
the corrective action.
■
Verify and Change Transmitter Parameter
Setting and Values
The parameters related to the following items are
set at factory as specified in order.
• Input sensor type
• Connection of RTD
• Measurement range (measurement lower/
upper limit, unit)