Model YPP6200 Analog Input Rate/Totalizer
Instruction Manual
29
Display Functions and Messages
The meter displays various functions and messages during setup,
programming, and operation. The following table shows the main menu
functions and messages in the order they appear in the menu.
Display Parameter
Action/Setting
Description
setup
Setup
Enter
Setup
menu
Input
Input
Enter
Input
selection menu
mA
4-20 mA
Set meter for 4-20 mA input
volt
0-10 VDC
Set meter for
±
10 VDC input
Total
Total
Enable or disable totalizer features
d-SCAL
Dual-scale
Enter
d-SCAL
menu and select
Yes
for
dual- scale or
No
for single scale display
units
Units
Select the display units/tags
rate
Rate
Select the display units for rate
total
Total
Select the display units for total
Gtotal
Grand Total
Select the display units for grand total
Dec pt
Decimal point
Set decimal point for rate, total, grand total
prog
Program
Enter the
Program
menu
InCAL
Input
Calibration
Enter the
Input Calibration
menu
sCalE
Scale
Enter the
Scale
menu
Cal
Calibrate
Enter the
Calibrate
menu
Inp 1
Input 1
Calibrate input 1 signal or program input 1
value
Dis 1
Display 1
Program display 1 value
Inp 2
Input 2
Calibrate input 2 signal or program input 2
value (up to 32 points)
Dis 2
Display 2
Program display 2 value (up to 32 points)
Error
Error
Error, calibration not successful, check
signal or programmed value
T tb
Total time
base
Program total time base