Model YPP6200 Analog Input Rate/Totalizer
Instruction Manual
11
Rate/Totalizer
RATE DISPLAY
INDICATION
-99999 to 999999, lead zero blanking. “R” LED illuminates
while displaying rate.
TOTAL DISPLAY
& TOTAL
OVERFLOW
0 to 999,999; automatic lead zero blanking. “T” LED is
illuminated while displaying total or grand total.
Up to 999,999,999 with total-overflow feature. “
oF
” is
displayed to the left of total overflow and
▲
LED is
illuminated.
TOTAL
DECIMAL POINT
Up to five decimal places or none:
d.ddddd
,
d.dddd
,
d.ddd
,
d.dd
,
d.d
,
or
dddddd
Total decimal point is independent of rate decimal point.
TOTALIZER
Calculates total based on rate and field programmable
multiplier to display total in engineering units. Time base
must be selected according to the time units in which the
rate is displayed.
TOTALIZER
ROLLOVER
Totalizer rolls over when display exceeds 999,999,999.
Relay status reflects display.
TOTAL
OVERFLOW
OVERRIDE
Program total reset for automatic with 0.1 second delay
and set point 1 for 999,999
TOTALIZER
PRESETS
Up to eight, user selectable under setup menu. Any set
point can be assigned to total and may be programmed
anywhere in the range of the meter for total alarm
indication.
PROGRAMMABLE
DELAY
ON RELEASE
0.1 and 999.9 seconds; applied to the first relay assigned
to total or grand total.
If the meter is programmed to reset total to zero
automatically when the preset is reached, then a delay will
occur before the total is reset.
TOTAL RESET
Via front panel button, external contact closure on digital
inputs, automatically via user selectable preset value and
time delay, or through serial communications.
TOTAL RESET
PASSWORD
Total and grand total passwords may be entered to
prevent resetting the total or grand total from the front
panel.
NON-RESETTABLE
TOTAL
The grand total can be programmed as a non-resettable
total by entering the password “050873”.
!
Caution!
Once the Grand Total has been programmed
as “non-resettable” the feature
cannot
be
disabled.