5-10
IM WT310E-01EN
Relationship between Resetting Integration and START/STOP
Key Operations
The relationship is shown in the figure below.
Integrated
value
Elapsed
integration
time
Interruption
Start
Restart
Interruption
Reset
Restart
Automatic stop Reset
Set integration timer value
START
STOP
START
STOP
RESET
START
RESET
Data When a Power Failure Occurs during Integration
• Even if a power failure occurs during integration, the integrated results will be retained in memory. If
the power is restored after a failure, this instrument will be in the following conditions.
• Integration will be stopped.
• Both the START and STOP keys will be illuminated.
• Integration results up to the point when the power failure occurred will be displayed.
• After the power is restored, you cannot simply restart integration where you left off. Reset
integration before starting it again.
Integration Resume Function at Power Failure Recovery
When the integration resume function at power failure recovery is set to ON, the integration operation
can be resumed if a power failure occurs and recovers while integration is in progress.
Description
If this function is set to ON and a power failure occurs and then recovers while integration is in
progress (the START key is illuminated) or while integration is paused (the STOP key is illuminated),
this instrument behaves in the following manner.
• The integration result before the power failure is displayed, and this instrument enters a
integration paused state (the STOP key is illuminated).
• Integration can be restarted with the START key or a command.
• The integration data after restarting is added to the results before the power failure.
Turning the Function On
Turn the power on while holding down
SHIFT+FUNCTION A+VOLTAGE
.
A start message “WT300E/SYSTEM/START” appears, and then all the LEDs illuminate.
Hold down the keys until all the LEDs illuminate.
Then, “OPT.01/ON” appears.
Turning the Function Off
Performing the above procedure when the function is on will turn it off.
In this case, “OPT.01/OFF” appears.
Checking the On/Off State of the Function
From the menu select
UTILITY
(
SHIFT
+
SETUP
) →“
inFo
”→“
VEr.
”
For details how to select from the menu, see section 8.1.
If the function is on, display D shows “OPT.01.”
5.4 Notes about Using Integration