IM 05P01D31-81EN  page 4/12

■  UT32A/RSP

■  UT35A/RSP (Continued from page 3)

(Suffix code: Type 2=2)

Contact input

External contact input

DI11

DI12

DI13

DI14

DI15

COM

Common

DI11

DI12

COM

+5V

+5V

No-voltage 

contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

DI13

+5V

DI14

+5V

DI15

+5V

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

UT

301

302

303

304

305

306

301

302

303

304

305

306

Function can be assigned to the 

terminals with no function.

DI

E1-Terminal Area

301-306

(Suffix code: Type 2=1)

External contact output

Transistor contact rating: 24 V DC, 50 mA

DO12

DO11

COM

Common

UT

Contact input / Contact output

External contact input

DI11

DI12

COM

Common

DI11

DI12

COM

+5V

+5V

No-voltage 

contact

Transistor contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

UT

301

302

303

301

302

303

304

305

306

DI/DO 

Function can be 

assigned to the 

terminals with no 

function.

+

24 V DC loop power supply

21.6-28.0 V DC

(Max. 30 mA DC)

24 V DC loop power supply

505

506

LPS24

(Option code /LP)

(Suffix code: Type 2=2)

Contact output

External contact output

DO42

DO41

DO43

DO44

DO45

COM

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

Common

UT

501

502

503

504

505

506

DO

Transistor contact rating: 24 V DC, 50 mA

Function can be assigned 

to the terminals with no 

function.

E4-Terminal Area

501-506

E4-terminal area

E3-terminal area

E1-terminal area

101
102
103
104
105
106

107
108
109
110

111

501
502
503
504
505
506
507
508
509
510
511
512

407

401

408
409
410
411
412

301
302
303
304

305
306

201
202
203
204
205
206
207
208

210
211
212

101

-112

501

-512

401

-412

301

-306

201

-212

112

(Suffix code: Type 3=2)

Ethernet communication (with gateway function)

10BASE-T/100BASE-TX

RJ45 connector

Color
Lit
Unlit

Amber
100M bps
10M bps

Green
Linked
Active
Link failure

Color
Lit
Blink
Unlit

Upper side LED (baud rate)

Lower side LED (link activity)

RS-485

RSB(+)

RSA(-)

SG

407

408

409

ETHR

RS-485

SDB(+)

SDA(-)

RDB(+)

RDA(-)

SG

RS-485 communication

(Suffix code: 

Type 3=1)

407

408

409

410

411

RS485

E3-Terminal Area

401-412

(Suffix code: Type 3=4)

PROFIBUS-DP communication (with Modbus master)

Pin

1

2

Signal name

Description

VP

RxD/TxD-P

3 RxD/TxD-N

4 DGND
5 SHIELD

+5V bus power
Data signal 

(positive data receive/transmit)
Data signal 

(negative data recive/transmit)
Signal ground
Shield ground

RS-485

RSB(+)

RSA(-)

SG

407

408

409

PROF

If the UT is located at the end 

of a segment for the 

PROFIBUS

communication wiring,

terminating resistors are 

separately needed.

These are to be  prepared by 

users. (390 Ω: 2 pcs. 220 Ω: 

1 pc., or an active

terminator.)

VP

RxD/TxD-P

Data 

line

Data 

line

390

Ω

220Ω

390

Ω

RxD/TxD-N

DGND

CHK
RDY
ERR

LED
CHK

(red)

RDY

(green)

Lit

Unlit

ERR

(red)

User profile error

Normal

Normal

Not connected, or

communication

failure (flashing)

Normal

Communicating

successfully

No power, or 

Communication 

failure 

1
2
3
4
5

(Suffix code: Type 3=3)

CC-Link communication (with Modbus master)

RS-485

RSB(+)

RSA(-)

SG

407

408

409

CC-L

If the UT is located at 

the end of a segment 

for the CC-Link

communication wiring,

terminating resistors 

are separately needed.

These are to be  

prepared by users. 

(110 Ω: 1 pc.)

DA

DB

110

Ω

LED
CHK

(red)

L ERR

(red)

L RUN

(green)

Lit

Unlit

CHK

L RUN

L ERR

User profile error/

Address error

Normal

Normal

Pin

1
2

Signal name

Description

DA

DB

3

DG

4

SLD

5

FG

RX/TX +  signal

RX/TX -  signal

Flame ground

RX/TX signal ground

Shield

Normal

Communicating successfully

Communication failure 

(CRC error)

No carrier 

detected/

Communication 

timeout

1
2
3
4
5

(Suffix code: Type 3=5)

DeviceNet communication (with Modbus master)

RS-485

RSB(+)

RSA(-)

SG

407

408

409

DNET

If the UT is located at 

the end of a segment 

for the DeviceNet

communication wiring,

terminating resistors 

are separately needed.

These are to be  

prepared by users. 

(121 Ω: 1 pc.)

CAN_H

CAN_L

121

Ω

LED
CHK

(red)

MNS

(green

/red)

Lit/flashing

Unlit

User profile error

Normal

Pin

1
2

Signal name

Description

CAN_H

CAN_L

3

V+

4

V-

5

DRAIN

RX/TX + signal

RX/TX - signal

Shield/Drain wire

DeviceNet power supply 24V

DeviceNet power supply common

Normal, communicating 

successfully (green, lit).

Not connected (green, flashing).
Critical link failure (red, lit).

Connection timeout (red, flashing)

At power-on/Communication 

faulted (green/red, flashing)

No electricity

CHK

MNS

1
2
3
4
5

(Suffix code: Type1=-1)

(Suffix code: Type1=-0)

Retransmission output

4-20 mA DC or

0-20 mA DC

15 V DC loop power supply

14.5-18.0 V DC

(Max. 21 mA DC)

+

-

+

-

Default: 4-20 mA DC

Default: 

PV retransmission

Load resistance 600 

Ω

 or less

Retransmission output

(Equipped as standard)

PV input

TC input

RTD input

Voltage (mV, V) input

A

+

-

+

-

B

b

(Equipped

 as standard)

Control output

Relay contact output

NC

NO

COM

Contact rating: 250 V AC, 3 A

 

          30 V DC, 3 A (resistance load)

111

301
302
303
304
305
306

307
308
309
310
311
312

201
202
203
204
205
206
207
208

210

101
102
103
104
105
106

107
108
109
110

211

212

Current/voltage pulse output

0-20 mA DC,

4-20 mA DC,

Voltage pulse (12  V)

-

Heating/cooling control output

(Suffix code: Type 1=-2)

Cooling-side control output

Heating/cooling relay contact output

NO

Heating

-side

Cooling

-side

NO

COM

Contact rating:  240 V AC, 3 A

 

           30 V DC, 3 A (resistance load)

Position proportional control output

Resistance: 100 

Ω

 to 2.5 k

Ω

Feedback input

100%

0%

Relay contact output

HIGH

(direct)

LOW

(reverse)

COM

Contact rating: 240 V AC, 3A

    

       30 V DC, 3 A

 

     (resistance load)

+

-

Feedback input

Current (mA)

input

When feedback input is current

E1-terminal area

101

-112

301

-312

201

-212

101

102

103

101

102

103

310

311

312

310

311

312

202

203

201

202

203

202

203

205

206

205

206

101

102

103

+

205

206

Terminal wiring differs in Heating/cooling control and 

Position proportional control.

Refer to the terminals of Position proportional control 

output and Heating/cooling control output below.

Factory default: Control output is relay.

Can be used for 15 V DC loop 

power supply when not used for 

retransmission output.

PV

RET

(Equipped as standard)

Contact input

Contact rating: 12 V DC, 10 mA or more

External contact input

DI2

DI1

COM

AUTO when DI1=ON

MAN when DI1=OFF

STOP when DI2=ON

RUN when DI2=OFF

Common

DI2

DI1

COM

+5V

+5V

No-voltage

contact

Transistor 

contact

UT

UT

210

211

212

210

211

212

Function can be assigned to the terminals with no function.

DI

VALV

(Equipped

 as standard)

Contact output

External contact output (relay)

AL3

AL2

AL1

Relay contact rating: 240 V AC, 1 A

 

           30 V DC, 1 A (resistance load)

Alarm-3 output

(PV high limit)

Alarm-2 output

(PV low limit)

Alarm-1 output

(PV high limit)

Common

Common

Common

UT

104

105

106

107

108

109

ALM

OUT

OUT

RET/OUT2

Factory default: 

PV input type is 

undefined.

(Option code /HA)

Heater break alarm

Heater current detection input

CT1

CT2

COM

310

311

312

HBA

External contact output (transistor)

Transistor contact rating: 24 V DC, 50 mA

 

      

Heater break alarm-1

output

Heater break alarm-2

output

Common

HAL1

HAL2

COM

UT

307

308

309

Current/voltage pulse output

0-20 mA DC,

4-20 mA DC,

Voltage pulse (12 V)

+

-

Retransmission output

+

-

Default: 4-20 mA DC

Default: Undefined

0-20 mA DC,

4-20 mA DC

Control output

(Suffix code: Type1=-0, -1 or -2)

15 V DC loop power supply

14.5-18.0 V DC

(Max. 21 mA DC)

+

-

207

208

207

208

207

208

Can be used for retransmission output or 15 V DC loop power suppy when 

current/voltage pulse output is not used for control output.

Current output range can be changed.

In Position proportional type, can be used for retransmission output or 15 V DC 

loop power supply.

OUT

OUT2

112

Power supply

24 V AC/DC power supply

-

+

100-240 V AC power supply

Allowable range: 

       100-240 V AC (+10%/-15%)

       (free voltage)

       50/60 Hz shared

N

L

(24 V AC/DC power supply: 

Option code /DC)

110

111

110

111

112

112

N

L

Can not be used for retransmission output or 15 V 

DC loop power suppy when current/voltage pulse 

output is used for control output.

Can be used for retransmission output or 15 V DC 

loop power suppy when control output is not used.

Current output range can be changed.

E1 is displayed in terminal 

area when the parameter 

settings.

(Option code /RSP)

Remote input

RSP

Remote input

Default: 1-5 V DC

-

+

203

204

Specify within a 

range of 1-5 V DC, 

0-2 V DC,0-10 V DC

(Suffix code: 

Type 1=-2)

Wiring direction

+

24 V DC loop power supply

21.6-28.0 V DC

(Max. 30 mA DC)

-

24 V DC loop power supply

(Suffix code: Type 2=0 and 

option code /LP)

305

306

LPS24

(Suffix code: Type 2=2)

External contact output

Transistor contact rating: 24 V DC, 50 mA

DO12

DO11

COM

Common

UT

Contact input / Contact output

External contact input

DI11

DI12

COM

Common

DI11

DI12

COM

+5V

+5V

No-voltage 

contact

Transistor 

contact

Contact rating: 12 V DC, 10 mA or more

Factory default: No function

Factory default: No function

Factory default: No function

Factory default: No function

UT

UT

301

302

303

301

302

303

304

305

306

DI/DO 

Function can be 

assigned to the 

terminals with no 

function.

E1-Terminal Area

301-306

RS-485

SDB(+)

SDA(-)

RDB(+)

RDA(-)

SG

RS-485 communication

(Suffix code: 

Type 2=1)

301

302

303

304

305

RS485

RS-485

RSB(+)

RSA(-)

SG

RS-485 communication/24 V DC loop power supply

+

24 V DC loop power supply

21.6-28.0 V DC

(Max. 30 mA DC)

-

301

302

303

305

306

RS485/LPS24

(Suffix code: Type 2=1 and 

option code /LP)

CC-Link communication (with Modbus master)

(Suffix code: Type 3=3)

FG: Flame ground

SLD: Shield

DG: TX/RX signal ground

DB: RX/TX signal - signal

DA: RX/TX signal

CHK(red)

(Lit: User profile error/Adress error, Unlit: Normal

L ERR(red)

(Lit: Communication failure(CRC error), Unlit: Normal

L RUN(green)

(Lit: Normal, Unlit: No carrier detected/Communication timeout)

Not used

301

302

303

304

305

306

307

308

309

RS-485

RSB(+)

RSA(-)

SG

310

311

312

DB

DA

110Ω

CC-L

If the UT is located at the end of a 
segment for the CC-Link 
communication wiring,terminating 
resistors are separately needed.
These are to be  prepared by 

users. (110 Ω: 1 pc.)

Содержание UT32A/RSP

Страница 1: ...rman French and Spanish are available for the guide display 2 The LP option can be specified in the combination of Type 2 code any of 0 or 1 and Type 3 code any of 0 or 1 3 The HA option can be specified only when the Type 1 code is 0 or 2 4 When the CT option is specified the UT35A does not conform to the safety standards UL and CSA and CE marking Products with CT option are not intended for EEA ...

Страница 2: ...input for com putation etc Number of inputs See the table of Model and Suffix Codes Input type instrument range and measurement accuracy See the table below Input Type Instrument Range Accuracy Standard signal 0 400 to 2 000 V 0 2 of instrument range 1 digit 1 000 to 5 000 V 0 1 of instrument range 1 digit DC voltage 0 000 to 2 000 V 0 2 of instrument range 1 digit 0 00 to 10 00 V 0 1 of instrumen...

Страница 3: ...ires for wiring For RTD input use shielded wires that have low conductor resistance and cause no significant differences in resistance between the three wires Since the control output relay has a life span resistance load of 100 000 times use the auxiliary relay to perform ON OFF control The use of inductance L loads such as auxiliary relays motors and solenoid valves causes malfunction or relay f...

Страница 4: ... Relay contact output NC NO COM Contact rating 250 V AC 3 A 30 V DC 3 A resistance load 111 301 302 303 304 305 306 307 308 309 310 311 312 201 202 203 204 205 206 207 208 210 101 102 103 104 105 106 107 108 109 110 211 212 Current voltage pulse output 0 20 mA DC 4 20 mA DC Voltage pulse 12 V Heating cooling control output Suffix code Type 1 2 Cooling side control output Heating cooling relay cont...

Страница 5: ...ntrol type setup Input output setup Valve position adjustment Use Quick setting function Position proportional type Position proportional type For Position proportional type 3 Quick Setting Function Setting of Input and Output The Quick setting function is a function to easily set the basic function of the control ler Turn on the controller to start the Quick setting function This function allows ...

Страница 6: ...RM menu is displayed 1 2 3 4 5 The parameter AL1 alarm 1 type is displayed Press the SET ENTER key Press the SET ENTER key 5 6 Energized De energized Latch action Stand by action The alarm 1 type setpoint 02 PV low limit is registered After the setup is completed press the DISPLAY key or DISP key once to return to the Operation Display Symbol To change the alarm type change the last 2 digits of th...

Страница 7: ... User s Manual IM 05P01D31 01EN The MAN lamp goes off which means that the auto tuning completed normally 5 6 7 8 The setting range is 1 to 4 represent group numbers or R To perform auto tuning for the PID of group 1 set the parameter AT to 1 To quit the auto tuning set the parameter to OFF During auto tuning The MAN lamp blinks The OUT symbol appears The output values at 100 0 and 0 appear altern...

Страница 8: ...ystem data and hardware of extended function Nonresponding communication between hardware of extended function E1 to E4 terminal areas Faulty Contact us for repair Normal indication Normal indication Rightmost decimal point on PV display blinks Setup parameter PA ER Calibration value error Initialized to calibrated default value because of corrupted factory default value Faulty Contact us for repa...

Страница 9: ...Without Stand by action 0 PV low limit 02 Table below EASY Alarm type 2 digits 00 Disable 01 PV high limit 02 PV low limit 03 SP high limit 04 SP low limit 05 Deviation high limit 06 Deviation low limit 07 Deviation high and low limits 08 Deviation within high and low limits 09 Target SP high limit 10 Target SP low limit 11 Target SP deviation high limit 12 Target SP deviation low limit 13 Target ...

Страница 10: ...re not described in this manual See User s Manual IM 05P01D31 01EN Control Function Setting Parameter Menu symbol CTL Parameter symbol Name of Parameter Setting Range Initial value User setting Display level CNT Control type PID PID control ONOF ON OFF control 1 point of hysteresis ONOF2 ON OFF control 2 points of hysteresis 2P2L Two position two level control H C Heating cooling control PID or H ...

Страница 11: ...cation with checksum LADR Ladder communication CO M Coordinated master station CO S Coordinated slave station MBASC Modbus ASCII MBRTU Modbus RTU CO S1 Coordinated slave station Loop 1 mode CO S2 Coordinated slave station Loop 2 mode P P Peer to peer communication MBRTU EASY BPS Baud rate 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 19200 19 2k bps 38400 38 4k bps 19200 PRI ...

Страница 12: ...error status LA ER Ladder error status MCU MCU version DCU DCU version ECU1 ECU 1 version E1 terminal area ECU3 ECU 3 version E3 terminal area ECU4 ECU 4 version E4 terminal area PARA Parameter version H VER Product version SER1 Serial number 1 SER2 Serial number 2 MAC1 MAC address 1 E3 terminal area MAC2 MAC address 2 E3 terminal area MAC3 MAC address 3 E3 terminal area Parameter Display Level Pa...

Отзывы: