If you are using two or more groups of PID parameters, use the following table to record their setting values.

Parameter

n=2

n=3

n=4

R

P

I

D

OH

OL

MR

HYS

SU.HY

HY.UP
HY.LO

DR

SU.DR

Pc

Ic

Dc

OHc

OLc

HYSc

DB
PO

SU.PO

POc

n: group number

 Tuning Parameter 

Menu symbol: 

 

(TUNE)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(SC)

Super function

OFF: Disable

1: Overshoot suppressing function 

(normal mode)

2: Hunting suppressing function 

(stable mode)

 

Enables to answer the wider 

characteristic changes compared 

with response mode.

3: Hunting suppressing function 

(response mode)

 

Enables quick follow-up and short 

converging time of PV for the 

changed SP.

4: Overshoot suppressing function 

(strong suppressing mode)

 

Note: Setpoints 2 and 3 must be 

used in PID control or PI control. 

Disabled in the following controls:

 

1) ON/OFF control, 2) PD control, 

3) P control, 4) Heating/cooling 

control. 

Do not use the function for the 

control processes with response 

such as flow or pressure control.

OFF

EASY

(AT.TY)

Auto-tuning type

0: Normal

 

1: Stability

0

STD

(AR)

Anti-reset windup 

(excess integration 

prevention)

AUTO, 50.0 to 200.0%

AUTO

(OPR)

Output velocity limiter

OFF: Disable

 

0.1 to 100.0%/s

OFF

(MPON)

Manual preset output 

number selection

Select the output used in MAN mode 

when switched from AUTO to MAN 

mode.

OFF: Hold the control output in AUTO          

mode (bumpless)

1: Use manual preset output 1 (output 

bump)

2: Use manual preset output 2 (output 

bump)

3: Use manual preset output 3 (output 

bump)

4: Use manual preset output 4 (output 

bump)

5: Use manual preset output 5 (output 

bump)

OFF

 to

(MPO1 to MPO5)

Manual preset output 1 

to 5

-5.0 to 105.0% 

 

However, output is limited to the 

output high limit and low limit.

0.0%

Table 

below

Use the following table to record the manual preset output setting value.

Parameter

n=1

n=2

n=3

n=4

n=5

MPOn

 Zone Control Parameter

Menu symbol: 

 (ZONE)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

 to

(RP1 to RP3)

Reference point 1 to 3

Set reference points at which switch

-

ing is carried out between groups of 

PID constants according to the given 

temperature zone.

 

0.0 to 100.0% of PV input range (EU) 

 

(RP1 ≤ RP2 ≤ RP3)

100.0% 

of PV 

input 

range

Table 

below

STD

(RHY)

Zone PID switching 

hysteresis

Hysteresis can be set for switching at 

a reference point. 

0.0 to 10.0% of PV input range span 

(EUS)

0.5 % 

of PV 

input 

range 

span

(RDV)

Reference deviation

Set a deviation from SP. The PID for 

reference deviation is used if there 

is a larger deviation than the preset 

reference deviation.

 

OFF: Disable

 

0.0 + 1 digit to 100.0% of PV input 

range span (EUS)

OFF

For Zone control, set the setup parameter ZON (zone PID selection) to Zone PID se-

lection.

Use the following table to record the reference point setting value.

Parameter

n=1

n=2

n=3

RPn

 P Parameter (for Ladder Program) 

Menu symbol: 

 (PPAR)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

 to 

(P01 to P10)

P01 to P10 parameter

-19999 to 30000 (Set a decimal point 

position using LL50A Parameter Set-

ting Software.)

0

Table 

below

STD

Parameter

n=01

n=02

n=03

n=04

n=05

n=06

n=07

n=08

n=09

n=10

Pn

Setup Parameters

Hold down the PARAMETER key or PARA key and Left arrow key simultaneously for 3 

seconds to move from the Operation Display or Operation Parameter Setting Display to 

the Setup Parameter Setting Display.

Press the DISPLAY key or DISP key once to return to the Operation Display.

Menu

DISPLAY key

or DISP key

SET/ENTER key

PARAMETER key

or PARA key

key

key

key

key

key

Operation Dsipaly

Parameter

Parameter

Parameter

Parameter

Parameter

Parameter

END

Menu

END

Menu

END

END

Menu Display and 

Parameter Setting 

Display are changed 

in a circular pattern.

Move to the Operation Parameter Setting Display: 

          Hold down the PARAMETER key or PARA key for 3 sec.

Hold down PARAMETER key or PARA key and 

Left arrow key simultaneously for 3 sec.

Operation for Setting

·  To select the parameter setting displayed as the initial value, press the Down arrow 

key to move to the next parameter.

·  To change and set the parameter setting, press the SET/ENTER key to start the set-

point blinking. The blinking state allows you to make changes (setting mode). Use the 

Up/Down/Left/Right arrow keys to change the setpoint. Press the SET/ENTER key to 

register the setting.

Note that there are some parameters which are not displayed depending on the Model 

and Suffix codes, control type (CNT), etc. The parameters for professional setting mode 

(LEVL: PRO) are not described in this manual. See User’s Manual (IM 05P01D31-

01EN).

 Control Function Setting Parameter

Menu symbol: 

 (CTL)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(CNT)

Control type

PID: PID control

ONOF: ON/OFF control (1 point of 

hysteresis)

ONOF2: ON/OFF control (2 points of 

hysteresis)

2P2L: Two-position two-level control

H/C: Heating/cooling control

PID

 

or 

H/C

 

(for

 

Heat

-

ing/

Cooling 

type)

EASY

(SPGR.)

Number of SP groups

Set a number of SP groups to use.

1 to 4

4

STD

(ZON)

Zone PID selection

If set to “SP group number selection,” 

allows PID constants to be selected 

for each SP group.

 

If set to “Zone PID selection,” 

automatically selects PID constants 

according to the range set in the 

Reference point. 

0: SP group number selection 1

1: Zone PID selection (selection by PV)

2: Zone PID selection (selection by 

target SP)

3: SP group number selection 2

4: Zone PID selection (selection by SP) 

0

(PIDG.)

Number of PID groups

Set a number of PID groups to use. 

 

1 to 4

4

 PV Input Setting Parameter

Menu symbol: 

 (PV)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(IN)

PV input type

OFF: Disable

K1: -270.0 to 1370.0 

0

C / -450.0 to 2500.0

 

0

F

K2: -270.0 to 1000.0 

0

C / -450.0 to 2300.0

 

0

F

K3: -200.0 to 500.0 

0

C / -200.0 to 1000.0

 

0

F

J: -200.0 to 1200.0 

0

C / -300.0 to 2300.0

 

0

F

T1: -270.0 to 400.0 

0

C / -450.0 to 750.0

 

0

F

T2: 0.0 to 400.0 

0

C / -200.0 to 750.0

 

0

F

B: 0.0 to 1800.0 

0

C / 32 to 3300

 

0

F

S: 0.0 to 1700.0 

0

C / 32 to 3100

 

0

F

R: 0.0 to 1700.0 

0

C / 32 to 3100

 

0

F

N: -200.0 to 1300.0 

0

C / -300.0 to 2400.0

 

0

F

E: -270.0 to 1000.0 

0

C / -450.0 to 1800.0

 

0

F

L: -200.0 to 900.0 

0

C / -300.0 to 1600.0

 

0

F

U1: -200.0 to 400.0 

0

C / -300.0 to 750.0

 

0

F

U2: 0.0 to 400.0 

0

C / -200.0 to 1000.0

 

0

F

W: 0.0 to 2300.0 

0

C / 32 to 4200

 

0

F

PL2: 0.0 to 1390.0 

0

C / 32.0 to 2500.0

 

0

F

P2040: 0.0 to 1900.0 

0

C / 32 to 3400

 

0

F

WRE: 0.0 to 2000.0 

0

C / 32 to 3600

 

0

F

JPT1: -200.0 to 500.0 

0

C / -300.0 to 1000.0

 

0

F

JPT2: -150.0 to 150.0 

0

C / -200.0 to 300.0

 

0

F

PT1: -200.0 to 850.0 

0

C / -300.0 to 1560.0

 

0

F

PT2: -200.0 to 500.0 

0

C / -300.0 to 1000.0

 

0

F

PT3: -150.00 to 150.00 

0

C / -200.0 to 300.0

 

0

F

0.4-2V: 0.400 to 2.000 V

1-5V: 1.000 to 5.000 V

0-2V: 0.000 to 2.000 V

0-10V: 0.00 to 10.00 V

-1020: -10.00 to 20.00 mV

0-100: 0.0 to 100.0 mV

OFF

EASY

(UNIT)

PV input unit

-: No unit, C: Degree Celsius

 

-: No unit, - -: No unit, - - -: No unit, 

F: Degree Fahrenheit

C

EASY

(RH)

Maximum value of PV 

input range

Depends on the input type.

- For temperature input -

Set the temperature range that is 

actually controlled. (RL<RH)

- For voltage / current input -

Set the range of a voltage / current 

signal that is applied.

The scale across which the voltage/

current signal is actually controlled 

should be set using the maximum 

value of input scale (SH) and mini-

mum value of input scale (SL).

(Input is always 0% when RL = RH.)

Depends 

on the 

input type

(RL)

Minimum value of PV 

input range

Depends 

on the 

input type

(SDP)

PV input scale decimal 

point position

0: No decimal place

1: One decimal place

2: Two decimal places

3: Three decimal places

4: Four decimal places

Depends 

on the 

input type

(SH)

Maximum value of PV 

input scale

-19999 to 30000, (SL<SH),

| SH - SL | ≤ 30000

Depends 

on the 

input type

(SL)

Minimum value of PV 

input scale

Depends 

on the 

input type

(BSL)

PV input burnout action

OFF: Disable

UP: Upscale

DOWN: Downscale

Depends 

on the 

input type

STD

(A.BS)

PV analog input bias

-100.0 to 100.0% of each input range 

span (EUS)

0.0 % of 

PV input 

range 

span

(A.FL)

PV analog input filter

OFF, 1 to 120 s

OFF

W: W-5% Re/W-26% Re(Hoskins Mfg.Co.). ASTM E988, WRE: W97Re3-W75Re25

 RSP Input Setting Parameter (E1-terminal Area)

Menu symbol: 

 (RSP)

Parameter 

symbol

Name of Parameter

Setting Range

Initial 

value

User 

setting

Display 

level

(IN)

RSP remote input type

0.4-2V: 0.400 to 2.000 V

1-5V: 1.000 to 5.000 V

0-2V: 0.000 to 2.000 V

0-10V: 0.00 to 10.00 V

1-5V

EASY

(UNIT)

RSP remote input unit

-: No unit, C: Degree Celsius

-: No unit, - -: No unit, - - -: No unit,

F: Degree Fahrenheit

C

(RH)

Maximum value of RSP 

remote input range

Set the range of a voltage signal that 

is applied.

The scale across which the voltage 

signal is actually controlled should be 

set using the maximum value of input 

scale (SH) and minimum value of 

input scale (SL).

(Input is always 0% when RL = RH.)

Depends 

on the 

input type

(RL)

Minimum value of RSP 

remote input range

Depends 

on the 

input type

(SDP)

RSP remote input scale 

decimal point position

0: No decimal place

1: One decimal place

2: Two decimal places

3: Three decimal places

4: Four decimal places

Depends 

on the 

input type

(SH)

Maximum value of RSP 

remote input scale

-19999 to 30000, (SL<SH),

| SH - SL | ≤ 30000

Depends 

on the 

input type

EASY

(SL)

Minimum value of RSP 

remote input scale

(BSL)

RSP remote input burn-

out action

OFF: Disable

UP: Upscale

DOWN: Downscale

Depends 

on the 

input type

STD

Содержание UT32A/RSP

Страница 1: ...rman French and Spanish are available for the guide display 2 The LP option can be specified in the combination of Type 2 code any of 0 or 1 and Type 3 code any of 0 or 1 3 The HA option can be specified only when the Type 1 code is 0 or 2 4 When the CT option is specified the UT35A does not conform to the safety standards UL and CSA and CE marking Products with CT option are not intended for EEA ...

Страница 2: ...input for com putation etc Number of inputs See the table of Model and Suffix Codes Input type instrument range and measurement accuracy See the table below Input Type Instrument Range Accuracy Standard signal 0 400 to 2 000 V 0 2 of instrument range 1 digit 1 000 to 5 000 V 0 1 of instrument range 1 digit DC voltage 0 000 to 2 000 V 0 2 of instrument range 1 digit 0 00 to 10 00 V 0 1 of instrumen...

Страница 3: ...ires for wiring For RTD input use shielded wires that have low conductor resistance and cause no significant differences in resistance between the three wires Since the control output relay has a life span resistance load of 100 000 times use the auxiliary relay to perform ON OFF control The use of inductance L loads such as auxiliary relays motors and solenoid valves causes malfunction or relay f...

Страница 4: ... Relay contact output NC NO COM Contact rating 250 V AC 3 A 30 V DC 3 A resistance load 111 301 302 303 304 305 306 307 308 309 310 311 312 201 202 203 204 205 206 207 208 210 101 102 103 104 105 106 107 108 109 110 211 212 Current voltage pulse output 0 20 mA DC 4 20 mA DC Voltage pulse 12 V Heating cooling control output Suffix code Type 1 2 Cooling side control output Heating cooling relay cont...

Страница 5: ...ntrol type setup Input output setup Valve position adjustment Use Quick setting function Position proportional type Position proportional type For Position proportional type 3 Quick Setting Function Setting of Input and Output The Quick setting function is a function to easily set the basic function of the control ler Turn on the controller to start the Quick setting function This function allows ...

Страница 6: ...RM menu is displayed 1 2 3 4 5 The parameter AL1 alarm 1 type is displayed Press the SET ENTER key Press the SET ENTER key 5 6 Energized De energized Latch action Stand by action The alarm 1 type setpoint 02 PV low limit is registered After the setup is completed press the DISPLAY key or DISP key once to return to the Operation Display Symbol To change the alarm type change the last 2 digits of th...

Страница 7: ... User s Manual IM 05P01D31 01EN The MAN lamp goes off which means that the auto tuning completed normally 5 6 7 8 The setting range is 1 to 4 represent group numbers or R To perform auto tuning for the PID of group 1 set the parameter AT to 1 To quit the auto tuning set the parameter to OFF During auto tuning The MAN lamp blinks The OUT symbol appears The output values at 100 0 and 0 appear altern...

Страница 8: ...ystem data and hardware of extended function Nonresponding communication between hardware of extended function E1 to E4 terminal areas Faulty Contact us for repair Normal indication Normal indication Rightmost decimal point on PV display blinks Setup parameter PA ER Calibration value error Initialized to calibrated default value because of corrupted factory default value Faulty Contact us for repa...

Страница 9: ...Without Stand by action 0 PV low limit 02 Table below EASY Alarm type 2 digits 00 Disable 01 PV high limit 02 PV low limit 03 SP high limit 04 SP low limit 05 Deviation high limit 06 Deviation low limit 07 Deviation high and low limits 08 Deviation within high and low limits 09 Target SP high limit 10 Target SP low limit 11 Target SP deviation high limit 12 Target SP deviation low limit 13 Target ...

Страница 10: ...re not described in this manual See User s Manual IM 05P01D31 01EN Control Function Setting Parameter Menu symbol CTL Parameter symbol Name of Parameter Setting Range Initial value User setting Display level CNT Control type PID PID control ONOF ON OFF control 1 point of hysteresis ONOF2 ON OFF control 2 points of hysteresis 2P2L Two position two level control H C Heating cooling control PID or H ...

Страница 11: ...cation with checksum LADR Ladder communication CO M Coordinated master station CO S Coordinated slave station MBASC Modbus ASCII MBRTU Modbus RTU CO S1 Coordinated slave station Loop 1 mode CO S2 Coordinated slave station Loop 2 mode P P Peer to peer communication MBRTU EASY BPS Baud rate 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 19200 19 2k bps 38400 38 4k bps 19200 PRI ...

Страница 12: ...error status LA ER Ladder error status MCU MCU version DCU DCU version ECU1 ECU 1 version E1 terminal area ECU3 ECU 3 version E3 terminal area ECU4 ECU 4 version E4 terminal area PARA Parameter version H VER Product version SER1 Serial number 1 SER2 Serial number 2 MAC1 MAC address 1 E3 terminal area MAC2 MAC address 2 E3 terminal area MAC3 MAC address 3 E3 terminal area Parameter Display Level Pa...

Отзывы: